1.4 Precautions When Combining Products
Precautions When Combining MP3200 Units
1-14
1.4
Precautions When Combining Products
The following precautions must be observed when combining the MP3200 Units and Optional Modules.
Precautions When Combining MP3200 Units
There are restrictions in the order in which you can connect the Units. Build the Rack by connecting each
Unit in the order that is shown below.
Precautions When Combining Optional Modules
When combining Optional Modules, make sure the following conditions are met.
• The output current of the Power Supply Unit
*
must be held to approximately 75% (approximately 9 A)
or less of the rated current capacity.
* This is the total of the maximum internal current consumption of the Base Units and Optional Modules that are con-
nected to the Power Supply Unit.
The Units will not operate if they are connected in the wrong order (e.g., if the Base Unit is connected
to the left side of the Power Supply Unit).
Power Supply Unit
CPU Unit
Base Unit
Rack Expansion
Interface Unit
(for Main Rack or
Expansion Rack)
Note
Always attach the front covers to unused slots on the Base Unit.
Note