351
■
n3-23: Overexcitation Braking Operation
No.
(Hex.)
Name
Description
Default
(Range)
n3-23
(057B)
Overexcitation Braking
Operation
Sets the direction of motor rotation where the drive will enable overexcitation.
0
(0 - 2)
0 : Disabled
1 : Enabled Only when Rotating FWD
2 : Enabled Only when Rotating REV
Note:
When
n3-23 = 1, 2
, the drive enables overexcitation only in the direction of motor rotation in which a regenerative load is applied. Increased
motor loss can decrease
ov [Overvoltage]
faults.