46
YASKAWA
TOEPC71061732E HV600 Drive Installation & Primary Operation
Figure 7.25 Install the Electrical Wires
3.
Install the front cover and the keypad to their initial positions.
Note:
• For knock-out holes that you do not use for control circuit wiring, install the included rubber waterproofing grommets. For knock-
out holes that you do use for control circuit wiring, install the correct conduit to keep the protection level.
• The knock-out holes for main circuit wiring do not have rubber grommets. Install the correct conduit to keep the IP55/UL Type 12
protection level.
A - Rubber grommets
■
Wiring the Main Circuit Terminal Block Using Procedure F
Main Circuit Terminal Block Wiring Procedure
1.
Remove the keypad and front cover.
2.
Remove the terminal block bolt.
Note:
When you use terminals - and +1 and these terminals have covers, remove them to install the wire.
A - Bolt
Figure 7.26 Remove the Terminal Block Bolts
3.