YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
357
Code
Name
Causes
Possible Solutions
Parameter
b1-04 = 1 [Reverse Operation Selection =
Reverse Disabled]
and you did Z Pulse Offset
Tuning.
•
If the machine prevents reverse rotation, disconnect the motor
from the machinery, set
b1-04 = 0 [Reverse Enabled]
, then do Z
Pulse Offset Tuning. When tuning is complete, set
b1-04 = 1
[Reverse Disabled]
.
•
If the machine does not prevent reverse rotation, set
b1-04 = 0
and do Z Pulse Offset Tuning.
The motor vibrates during tuning.
•
Increase the values set in
n8-03 [Pole Position Detection Time]
and
n8-04 [Pole Alignment Time]
.
•
Decrease the value set in
n8-02 [Pole Alignment Current Level]
.
The encoder is damaged.
•
Examine the signal output from the encoder.
•
Replace the encoder.
Code
Name
Causes
Possible Solutions
Er-25
HighFreq Inject Param Tuning Err
The motor data is incorrect.
Do Stationary Auto-Tuning again.
Note:
If the drive detects
Er-25
after doing Stationary Auto-Tuning,
the motor may not be able to use high frequency injection
control. Contact Yaskawa or your nearest sales representative
for more information.
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...