5.4 Main Circuit Terminal Block Wiring Procedure
YASKAWA
TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
381
◆
Wire the Main Circuit Terminal Block with Procedure B
■
Notes on Wiring the Main Circuit Terminal Block
Note:
•
After the wiring, do not twist or shake the electrical wires too much.
•
Be sure to use only wires with the correct size, stripped wire length, and tightening torque as specified by Yaskawa.
•
Use tools that fit the shape of the screw head to tighten and loosen the terminal block screws.
•
Make sure that there are no loose stranded wires or frayed wires after wiring is complete.
■
Main Circuit Terminal Block Wiring Procedure
Remove the terminal cover before wiring the main circuit terminal block.
1.
Remove the screws on the terminal block cover and pull the terminal block cover away from the drive. Pull the
wiring cover away from the drive to remove the wiring cover after removing the terminal block cover.
Note:
6-Phase/12-pulse drives (models: Txxx) do not have the wiring covers.
A - Terminal block cover
B - Wiring cover
Figure 5.41 Remove the Wiring Cover
2.
Remove the terminal block nut.
A - Nut
Figure 5.42 Remove the Terminal Block Nut
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 18: ...i 2 Using the Product Safely 18 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 72: ...1 7 Storage Guidelines 72 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 336: ...4 10 Installation Methods 336 YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting...
Page 565: ...YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance Troubleshooting 565...