background image

Page 12

System Diagram for Modbus/TCP Pass-through

YASKAWA
Portal

Ethernet Cable

3rd Party Data Logger
/ SCADA

The gateway can be used as a Modbus/TCP server, connect to a third-party SCADA system, 
and forward various commands to the daisy chain.

Inverter or ESS

RS485 Cable

3rd Party

Portal

Summary of Contents for ENC-G5

Page 1: ...Quick Guide for ENC G5 09 22 2022 Revision 1 ...

Page 2: ...ensions and Interfaces LED Indicators Typical System Design and Diagrams Hardware Installation Mounting External in a DAS Box Grounding the Unit Wiring Using the APP Check the Internet Connection Modbus Device Settings Modbus TCP Reset Restart Internal In Wire box of The Inverter ...

Page 3: ...S485 wiring problems Modbus TCP pass thru The 3rd party controller can R W the RS485 daisy chain at any time through Modbus TCP Built in 4G modem SIM card included when purchasing the connectivity package which includes the ENC G5 gateway card a SIM card and access to the YConnect Pro Portal Easy mass deployment and configuration via APP using built in Bluetooth Low Energy BLE Plastic DIN rail enc...

Page 4: ...20 ohms Isolation 2 5 kV AUX Interface No of Ports 1 3 pole Terminal Block Protocol Modbus RTU Modbus RTU Mode Slave RS485 Pass thru Terminator for RS485 120 ohms Isolation 2 5 kV Ethernet Interface 10 100BaseTX Ports RJ45 connector 1 Connect to the Cloud Applications MQTT Forward Raw Data to 3rd Party HTTPS MQTT Unidirectional SCADA controllers on the same LAN subnet Modbus TCP ...

Page 5: ...a Connectors 1 SMA female Bluetooth Interface Standard BLE 4 2 Antenna Built in Power Parameters Input Voltage 9 to 24 Vdc Power Consumption 2 5 W Max 5 W Power Connector Terminal Block Environmental Limits Operating Temperature 30 to 85 22 to 185 F Natural convection Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 85 non condensing ...

Page 6: ...ensions 70 mm 100 mm 28 mm 2 76 in x 3 94 in x 1 10 in Weight 73g 0 16 lb Standards and Certifications DoC CE EMC EN 55032 EN 55035 EN 61000 3 2 EN 61000 3 3 CE RED EN 301 908 EN 300 328 EN 301 489 1 17 52 EN 62368 1 CE LVD EN 62368 1 FCC SDoC Part 15B FCC ID Part 15C ...

Page 7: ...Page 6 Dimensions and Interfaces ...

Page 8: ...al installation option A A B G Vin GND A B G B Terminating Resistance Switch Default 1 ON Caution If the length of the cable connecting to RS485 port or AUX port of the gateway is over 1000 meters the Switch button must be set to ON Power Switch POWER ON Caution Before configuring the gateway pay attention to set the power switch to ON ...

Page 9: ...for 5 years Both of these products come with the capability of accessing the Yaskawa Solectria Solar YConnect Pro Portal for 5 years Note The ENC gateway is not compatible with third party sourced SIM card The Yaskawa Solectria Solar technical support team will not be able to assist in the implementation of third party SIM cards with this gateway ENC gateway hardware warranty is valid by default w...

Page 10: ... 52 209 TCP 443 with destination solrenview com IP 209 160 64 80 Internet interface 4G ENC SIM card provided in the ENC PORT C5XX Connectivity Packages supports AT T T mobile networks After the gateway is powered on and working it will select and connect to the provider network with the strongest or most stable signal If you are interested in a Yaskawa Solectria Solar Connectivity Package please c...

Page 11: ...n being executed IP ACK Indicates whether the gateway is connected to the YASKAWA Solectria portal or target server via the Internet Light Off BLE Hardware Error Blink No Active Connection Light On Phone Connected Light Off Found Nothing Light On Some Devices Found Light Off Unable to connect to LAN router or 4G base station Blink Connected to a LAN router or 4G base station but not yet connected ...

Page 12: ...ough YASKAWA Portal RS485 Cable 3rd Party Data Logger SCADA The RS485 interface of the third party controller is connected to the AUX interface of the gateway which is equivalent to a direct transmission connection with a daisy chain Inverter or ESS RS485 Cable 3rd Party Portal ...

Page 13: ... through YASKAWA Portal Ethernet Cable 3rd Party Data Logger SCADA The gateway can be used as a Modbus TCP server connect to a third party SCADA system and forward various commands to the daisy chain Inverter or ESS RS485 Cable 3rd Party Portal ...

Page 14: ...ty Data Logger SCADA The gateway allows users to connect different brands and models of hardware in the same daisy chain via RS485 The connected hardware needs to be pre compatible with the YASKAWA Solectria Solar YConnect Pro Portal Inverter or ESS RS485 Cable Model A Model B Meter Weather Sensor EV Charger ...

Page 15: ...rter Inverter Wire Box RS485 YASKAWA Portal Primary MQTT YASKAWA Connect Pro APP Router When the inverters are monitored via the gateway a unique RS 485 address for each inverter can be set up through the LCD interface Up to 32 inverters can be connected in the daisy chain network ...

Page 16: ... 2 Phillips bit 2 Replace the screws with the 3 standoffs included in the gateway kit Install the gateway by carefully align ing the 6 PIN connector in the upper left hand corner of the communica tion board Install the 3 screws into the stand offs to secure the gateway in place Install the 3 screws and torque to 7 in lbs using a 2 Phillips bit 6 PIN Connector 6 PIN Header 3 ...

Page 17: ...g the 5 Pin Connector provided in the gateway kit NOTE The 5 Pin Connector is installed on the port on the bottom of the inverter communication board behind the gateway The RJ45 LAN cable is inserted into the Ethernet port of the gateway The LAN cable must be able to access the Internet without port filtering behind the firewall 5 A B G Vin GND A B G RS485 of 3rd Party Data Logger RS485 Inverter D...

Page 18: ...again that the gateway s power switch is set to on Pass the cable through the disassembled cable gland parts in sequence then tighten the cable glands again Screw one end of the antenna cable into the cable connector of the gateway Screw the other end of the antenna cable into the antenna ...

Page 19: ...crew driver to fix the DIN rail clip and the upper cover of the housing together with M4 flat head screws Screw Driver M4 Flat Head Screw DIN rail Clip Cover Base 2 Put the ENC gateway on the base of the housing and tighten it at the position shown in the figure with standoffs ...

Page 20: ...nd lower housings according to the positions of the screw holes and fasten the two parts together with M3 screws Flat Mounting External in a DAS Box b c Put the parts in position in the order of a b c and tighten the corresponding screws a ...

Page 21: ...the position shown in the figure and the gateway is grounded Wiring RS485 Cable 3rd Party Data Logger SCADA Inverter or ESS RS485 Cable Model A Model B Meter Weather Sensor EV Charger 5 Pole Terminal Block on gateway 3 Pole Terminal Block on gateway A B G Vin GND A B G ...

Page 22: ...tion O M Service APP Settings For installers to set up hardware devices without a registered account Smart Link Next Tighten and power on Bluetooth on the phone is enabled Location permission has been turned on Make sure your phone can connect to the Internet when you run the app for the first time The APP needs to sync some important data from the cloud Click smart link and the app will prompt yo...

Page 23: ...12123000203 Status Processing SN barcode The BLE name includes the SN The gateway serial number SN is included in the BLE signal name and the app will list the scanned signals Select the SN consistent with the target gateway label and click to enter While connecting and configuring the gateway interface the app will inform users if there are any networking issues to address ...

Page 24: ...Baud Rate Modbus ID 2022 09 16 10 30 32 GMT 6 FA1 C 7012123000203 1 2200 mqtt solectria com 1884 Online Ethernet Connected 9600 N8 1 1 10 FA1 7012123000203 Device Settings Internet Settings More Refresh Ensuring that the gateway can connect to the Internet is the most important step The gateway connects to the Internet through 4G by default if connection to the Internet via Ethernet is desired sel...

Page 25: ...er Model not scanned Status ID 5 Scan Enter Model not scanned Status Modbus ID Range Save 1 5 PVI25KTL DO US 480 SOL Supports the discontinuous ID in the range of 1 246 Modbus ID 165 222 253 254 should not be used Add new device ID Settings Baud Rate Modbus ID Range Gateway Mode Raw Data Forward Modbus TCP Upgrade Firmware Reboot Reset 9600 N 8 1 GW FOM None The gateway is config ured with a defau...

Page 26: ... Client IP Port 192 168 1 101 3845 Ethernet Settings Save Modbus TCP Port DHCP Auto DNS 502 Usually the modbus tcp client is in the same subnet as the gateway and can automatically connect to the gateway If an exception occurs first check whether the two are in the same subnet or whether the Ethernet cable is properly plugged in ENC G5 gateway supports 1 Modbus TCP client User can change Modbus TC...

Page 27: ...ard Modbus TCP Upgrade Firmware Reboot Reset 9600 N 8 1 GW FOM None Click Reset the gateway will clear all the current setting parameters and restore the factory settings Click Reboot the gateway will automatically power off and restart without changing the current setting parameters ...

Page 28: ...Page 27 Monitoring Support Phone 978 683 9700 Option 5 Hours 8 30 AM to 5 30 PM EST Mon Fri Email monitoring solectria com ...