6.1 I/O Signals
6.1.1 Input Signals
6-4
/RGRT (Registration Input) Signal
This is the latch signal that is used for registration (external positioning).
You can change the setting for the /RGRT signal with PnB12.
/MODE 0/1 (Mode Switch Input) Signal
You can use this signal to change between Mode 0 (program table operation) and Mode 1 (jog
speed table operation or homing).
You can change the setting for the /MODE 0/1 signal with PnB03.
/START-STOP (Program Table Operation Start-Stop Input
Signal)
This signal is used to start and stop operation for the program step that is specified by the
/SEL0 to /SEL7 (Program Step Selection Inputs) signals.
Parameter
Meaning
When Enabled
Classification
PnB11
0000h
(default setting)
Starts deceleration during homing when the
/DEC signal turns ON (closes).
After restart
Setup
0001h
Starts deceleration during homing when the
/DEC signal turns OFF (opens).
0002h
Sets the homing limit switch so that it is always
ON.
0003h
Sets the homing limit switch so that it is always
OFF.
Type
Signal
Connector Pin No.
Signal Status
Meaning
Input
/RGRT
CN1-12
ON (closed)
The current position has reached the latch posi-
tion.
OFF (open)
The current position has not reached the latch
position, or has passed the latch position.
Parameter
Meaning
When Enabled
Classification
PnB12
0000h
(default setting)
Starts registration by switching the /RGRT signal
from OFF (open) to ON (closed).
After restart
Setup
0001h
Starts registration by switching the /RGRT signal
from ON (closed) to OFF (open).
0002h,
0003h
Does not start registration.
Type
Signal
Pin No.
Signal Status
Meaning
Input
/MODE
0/1
CN11-3
ON (closed)
Mode 0 (Program Table Operation)
OFF (open)
Mode 1 (jog speed table operation or homing)
Parameter
Meaning
When Enabled
Classification
PnB03
0000h
(default setting)
When input signal is ON (closed), mode is set to
Mode 0.
After restart
Setup
0001h
When input signal is OFF (open), mode is set to
Mode 0.
0002h
Always Mode 0.
0003h
Always Mode 1.
Type
Signal
Pin No.
Signal Status
Meaning
Input
/START-
STOP
CN11-5
ON (closed)
Turn ON this signal to start operation for the
program step that is specified by the /SEL0 to
/SEL7 (Program Step Selection Inputs) signals.
OFF (open)
Turn OFF this signal to stop program table oper-
ation and decelerate the motor to a stop.