SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
ON : Selects motor 3
OFF : Select motor 1 or motor 2 (Select the terminal assigned
H1-xx = 16 [Motor 2 Selection]
)
Note:
•
Set
H1-xx = 16
, when setting
H1-xx = 39
. If
H1-xx = 39
is set while
H1-xx = 16
is not set,
oPE03 [Multi-Function Input Setting Err]
is detected.
•
Refer to
Motor Switch Function on page 216
for details.
■
3A: Micro Speed Gain1
Setting Value
Function
Description
3A
Micro Speed Gain1
Multiplies the gain set in
S2-16 [Micro Speed Gain1]
by the final step of frequency reference when the terminal is ON.
■
3B: Micro Speed Gain2
Setting Value
Function
Description
3B
Micro Speed Gain2
Multiplies the gain set in
S2-17 [Micro Speed Gain2]
by the final step of frequency reference when the terminal is ON.
■
40: Forward RUN (2-Wire)
Setting Value
Function
Description
40
Forward RUN (2-Wire)
Input the Forward Run command for 2-wire sequence 1. Use it paired with the
Reverse Run Command (2-Wire Seq) [H1-xx =
41]
.
ON : Forward Run
OFF : Run Stop
Note:
•
When the both Forward run command and Reverse run command terminals have been turned ON, the drive detects
EF [FWD/REV Run
Command Input Error]
(minor fault), and the motor ramps to stop.
•
The Forward run/Reverse run command is set to terminals S1 and S2 when the drive is initialized using a 2-wire sequence.
■
41: Reverse RUN (2-Wire)
Setting Value
Function
Description
41
Reverse RUN (2-Wire)
Input the Reverse run command for 2-wire sequence 1. Use it paired with the
Forward Run Command (2-Wire Seq) [H1-xx =
40]
.
ON : Reverse Run
OFF : Run Stop
Note:
•
When the both Forward run command and Reverse run command terminals have been turned ON, the drive detects
EF [FWD/REV Run
Command Input Error]
(minor fault), and the motor ramps to stop.
•
The Reverse run command is set to terminal S2 when the drive is initialized using a 2-wire sequence.
■
44: Add Offset Frequency 1 (d7-01)
Setting Value
Function
Description
44
Add Offset Frequency 1
(d7-01)
Sets the function to add the offset frequency set in
d7-01 [Offset Frequency 1]
to the frequency reference when the terminal
activates.
Note:
Refer to
d7: Offset Frequency on page 632
for more information.
■
45: Add Offset Frequency 2 (d7-02)
Setting Value
Function
Description
45
Add Offset Frequency 2
(d7-02)
Sets the function to add the offset frequency set in
d7-02 [Offset Frequency 2]
to the frequency reference when the terminal
activates.
Note:
Refer to
d7: Offset Frequency on page 632
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...