596
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
■
b4-03: Terminal M1-M2 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-03
(0B30)
Expert
Terminal M1-M2 ON-
Delay Time
Sets the delay time to activate the contact after the function set in
H2-01
activates.
0 ms
(0 - 65000 ms)
■
b4-04: Terminal M1-M2 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-04
(0B31)
Expert
Terminal M1-M2 OFF-
Delay Time
Sets the delay time to deactivate the contact after the function set in
H2-01
deactivates.
0 ms
(0 - 65000 ms)
■
b4-05: Terminal M3-M4 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-05
(0B32)
Expert
Terminal M3-M4 ON-
Delay Time
Sets the delay time to activate the contact after the function set in
H2-02
activates.
0 ms
(0 - 65000 ms)
■
b4-06: Terminal M3-M4 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-06
(0B33)
Expert
Terminal M3-M4 OFF-
Delay Time
Sets the delay time to deactivate the contact after the function set in
H2-02
deactivates.
0 ms
(0 - 65000 ms)
■
b4-07: Terminal M5-M6 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-07
(0B34)
Expert
Terminal P2 ON-Delay
Time
Sets the delay time to activate the contact after the function set in
H2-03
activates.
0 ms
(0 - 65000 ms)
■
b4-08: Terminal M5-M6 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-08
(0B35)
Expert
Terminal P2 OFF-Delay
Time
Sets the delay time to deactivate the contact after the function set in
H2-03
deactivates.
0 ms
(0 - 65000 ms)
■
b4-09: Terminal P1-C1 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-09
(0B36)
Expert
Terminal P2-C2 ON-Delay
Time
Sets the delay time to activate the contact after the function set in
H2-04
activates.
0 ms
(0 - 65000 ms)
■
b4-10: Terminal P1-C1 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-10
(0B37)
Expert
Terminal P2-C2 OFF-Delay
Time
Sets the delay time to deactivate the contact after the function set in
H2-04
deactivates.
0 ms
(0 - 65000 ms)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...