![YASKAWA CIPR-GA50C series Technical Manual Download Page 498](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765498.webp)
498
YASKAWA
SIEPC71061753A GA500 Technical Manual
■
b4-01: Timer Function ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-01
(01A3)
Timer Function ON-Delay
Time
Sets the ON-delay time for the timer input.
0.0 s
(0.0 - 3000.0 s)
■
b4-02: Timer Function OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-02
(01A4)
Timer Function OFF-Delay
Time
Sets the OFF-delay time for the timer input.
0.0 s
(0.0 - 3000.0 s)
■
b4-03: Terminal M1-M2 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-03
(0B30)
Expert
Terminal M1-M2 ON-
Delay Time
Sets the delay time until the contact is turned ON after the function set with
H2-01
turns ON.
0 ms
(0 - 65000 ms)
■
b4-04: Terminal M1-M2 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-04
(0B31)
Expert
Terminal M1-M2 OFF-
Delay Time
Sets the delay time to deactivate the contact after the function set in
H2-01
deactivates.
0 ms
(0 - 65000 ms)
■
b4-05: Terminal M3-M4 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-05
(0B32)
Expert
Terminal M3-M4 ON-
Delay Time
Sets the delay time to activate the contact after the function set in
H2-02
activates.
0 ms
(0 - 65000 ms)
■
b4-06: Terminal M3-M4 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-06
(0B33)
Expert
Terminal M3-M4 OFF-
Delay Time
Sets the delay time to deactivate the contact after the function set in
H2-02
deactivates.
0 ms
(0 - 65000 ms)
■
b4-07: Terminal P2 ON-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-07
(0B34)
Expert
Terminal P2 ON-Delay
Time
Sets the delay time until the contact is turned ON after the function set with
H2-03
turns ON.
0 ms
(0 - 65000 ms)
■
b4-08: Terminal P2 OFF-Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
b4-08
(0B35)
Expert
Terminal P2 OFF-Delay
Time
Sets the delay time to deactivate the contact after the function set in
H2-03
deactivates.
0 ms
(0 - 65000 ms)
◆
b5: PID control
The drive has a PID control function. You can control drive output to adjust the proportional gain, integral time,
and derivative time that has an effect on the bias between the target value and the feedback value to match the
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...