3 Electrical Installation
YASKAWA Europe
TOEP C710606 96A - AC Drive A1000 IP54 Wallmount - Quick Start Guide
EN 13
3
Electrical Installation
The figure below shows the main and control circuit wiring.
<1> Multi-function digital input S3 is used for fan monitoring by default. See
Internal Cooling Fan on page 18
<2> Never short terminals SP and SN as doing so will damage the drive.When changing sink/source configuration, the wiring of the fan monitor has
Internal Cooling Fan on page 18
<3> Disconnect the wire jumper between H1 - HC and H2 - HC when utilizing the Safe Disable input.
Three-phase
power supply
200 to 400 V
50/60 Hz
R/L1
S/L2
T/L3
Mains Switch
(optional built-in)
Fuse
EMC
Filter
S
1
S
2
Safety
switch
+
㧙
+
+
+
+
M
U/T
1
V/T
2
W/T
U
V
W
3
Ground
Terminals -, +1, +2, B1, B2 are
for connection options. Never
connect power supply lines to
these terminals
Thermal relay
(option)
+
㧙
+
+
+
+
+
㧙
S
1
S
2
S
3
S
4
S
5
S
6
S
7
MP
DM
DM
RP
A
1
A
2
A
3
0 V
AC
R
R
S
S
IG
H
1
H
2
HC
Drive
B
1
1
2
B
2
2 k
Ω
S
8
SC
0 V
0 V
AC
FM
AM
AC
E (G)
<3>
㧙
+
24 V
+
V
MA
M
1
M
2
MB
MC
Jumper
Braking resistor
(option)
Forward Run / Stop
Reverse Run / Stop
Fan monitoring
Fault reset
Multi-speed step 1
Multi-speed step 2
External Baseblock
Jog speed
Multi-function
digtial inputs
(default setting)
Sink / Source mode
selection wire link
(default: Sink)
CN5-C
CN5-B
CN5-A
Option card connectors
Pulse Train Input (max 32 kHz)
Shield ground terminal
Multi-function
analog/ pulse
train inputs
Power 10.5 Vdc, max. 20 mA
Analog Input 1 (Frequency Reference Bias)
-10 to +10 Vdc (20 k
Ω
)
Analog Input 2 (Frequency Reference Bias)
-10 to +10 Vdc (20 k
Ω
)
0 or 4 to 20 mA (250
Ω
)
Analog Input 3 / PTC Input
(Aux. frequency reference)
-10 to +10 Vdc (20 k
Ω
)
−
V
Power supply, -10.5 Vdc, max. 20 mA
MEMOBUS/Modbus
comm. RS485/422
max. 115.2 kBps
Safe Disable inputs
Wire
jumper
Open
Safety relay /
controller
Termination resistor
(120
Ω
, 1/2 W)
DIP
Switch S2
Fault relay output
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
Multi-function relay output (During Run)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
Multi-function pulse train output
(Output frequency)
0 to 32 kHz (2.2 k
Ω
)
Multi-function analog output 1
(Output frequency)
-10 to +10 Vdc (2mA) or 4 to 20 mA
Multi-function analog output 2
(Output current)
-10 to +10 Vdc (2mA) or 4 to 20 mA
EDM (Safety Electronic Device Monitor)
Main Circuit
Control Circuit
shielded line
twisted-pair shielded line
main circuit terminal
control circuit terminal
R/L1
S/L2
T/L3
Motor
Shielded
Cable
M
3
M
4
Multi-function relay output (Zero Speed)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
M
5
M
6
Multi-function relay output (Speed Agree 1)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
SP
SN
AM
FM
V
I
V
I
DIP Switch S1
A2 Volt/Curr. Sel
DIP Switch S4
A3 Analog/PTC
Input Sel
PTC
AI
Off
On
DIP Switch S2
Term. Res. On/Off
Jumper S3
H1, H2
Sink/Source Sel.
Jumper S5
FM/AM Volt./Curr.
Selection
Terminal board
jumpers and switches
FM
+
㧙
AM
<2>
indicates IP54 enclosure
<1>