YASKAWA 62K-JIDR Manual Download Page 4

General

1.1  Copyright 

©

 VIPA GmbH

This document contains proprietary information of VIPA and is not to be disclosed or used

except in accordance with applicable agreements.

This material is protected by the copyright laws. It may not be reproduced, distributed, or

altered in any fashion by any entity (either internal or external to VIPA), except in accord-

ance with applicable agreements, contracts or licensing, without the express written con-

sent of VIPA and the business management owner of the material.

For permission to reproduce or distribute, please contact: VIPA, Gesellschaft für Visuali-

sierung und Prozessautomatisierung mbH Ohmstraße 4, D-91074 Herzogenaurach, Ger-

many

Tel.: +49 9132 744 -0

Fax.: +49 9132 744-1864

EMail: [email protected]

http://www.vipa.com

Every effort has been made to ensure that the information contained in

this document was complete and accurate at the time of publishing. Nev-

ertheless, the authors retain the right to modify the information.

This customer document describes all the hardware units and functions

known at the present time. Descriptions may be included for units which

are not present at the customer site. The exact scope of delivery is

described in the respective purchase contract.

Hereby, VIPA GmbH declares that the products and systems are in compliance with the

essential requirements and other relevant provisions. Conformity is indicated by the CE

marking affixed to the product.

For more information regarding CE marking and Declaration of Conformity (DoC), please

contact your local VIPA customer service organization.

VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V,

System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft

für Visualisierung und Prozessautomatisierung mbH.

SPEED7 is a registered trademark of profichip GmbH.

SIMATIC, STEP, SINEC, TIA Portal, S7-300 and S7-400 are registered trademarks of

Siemens AG.

Microsoft and Windows are registered trademarks of Microsoft Inc., USA.

Portable Document Format (PDF) and Postscript are registered trademarks of Adobe

Systems, Inc.

All other trademarks, logos and service or product marks specified herein are owned by

their respective companies.

Contact your local VIPA Customer Service Organization representative if you wish to

report errors or questions regarding the contents of this document. If you are unable to

locate a customer service centre, contact VIPA as follows:

All Rights Reserved

CE Conformity Declaration

Conformity Information

Trademarks

Information product sup-

port

VIPA HMI

General

Copyright 

©

 VIPA GmbH  

HB160 | TP | 62K-JIDR | en | 17-11

 

4

Summary of Contents for 62K-JIDR

Page 1: ...TP 62K JIDR Manual HB160 TP 62K JIDR en 17 11 VIPA HMI Touch Panel TP 610C RFID www vipa com en service support manual...

Page 2: ...62K JIDR_000_TP610C_RFID 3 EN 2017 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Page 3: ...t RFID reader 25 3 4 Connection to a PLC system 27 3 5 Operating system Windows Embedded CE 6 0 Prof 27 3 5 1 General 27 3 5 2 Structure 29 3 6 Communication via ActiveSync 33 3 7 Integrated Server 35...

Page 4: ...spective purchase contract Hereby VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions Conformity is indicated by the CE mar...

Page 5: ...Windows CE 6 0 Prof The manual is targeted at users who have a background in automation technology The manual consists of chapters Every chapter provides a self contained description of a specific top...

Page 6: ...artment n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the components described in this manual Hardware modifications...

Page 7: ...ules that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices...

Page 8: ...e grated RFID reader for access control and activation of machine controls n Windows CE 6 0 Prof n Processor Xscale 1 1GHz n Work memory 256Mbyte n User memory 512Mbyte n RFID reader n 380Mbyte memory...

Page 9: ...A USB B 2xEthernet RJ45 Switch 2 3 Structure 2 3 1 Overview 1 Slot for storage medium CF SD MMC 2 RFID reader 3 Connection for interfaces and power supply 4 Display with touch sensitive area touch scr...

Page 10: ...ack for Ethernet communication 7 RJ45 jack for Ethernet communication 8 Slot for DC 24V voltage supply 9 Slot for CF SD MMC storage medium Please make sure that the Touch Panel always has to be suppli...

Page 11: ...115 2kBaud n Serial bus connection in 2 wire technology using half duplex mode 9 pin SubD plug n Interface is compatible to the COM interface of a PC n Logical signals as voltage levels n Point to poi...

Page 12: ...el is an accumulator with a suitable charging circuit This accu mulator is maintenance free and does not need to be exchanged within the life span of the Touch Panel 2 3 3 Memory management The follow...

Page 13: ...e of the Touch Panel are the card slots for memory cards The cards are visibly covered by a security flap and are thus secured from slipping out Please take care to pull the security flap back before...

Page 14: ...ouch Panel in control cabinets and desks the following dimen sions are necessary Front panel width 1 5 6mm Installation cutting W x H 287 x 217mm Front panel W x H 304 x 233mm Rear panel W x H x D 285...

Page 15: ...mounting cut out 1 5 6mm The deviation from the plane for the panel cut out is 0 5mm This condition must be fulfilled for the mounted HMI device Permissible surface roughness in the area of the seal...

Page 16: ...tion voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14...

Page 17: ...single pulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data 2 6 1 62K JIDR CX O...

Page 18: ...tor Sub D 9 pin female Serial COM1 RS232 COM1 connector Sub D 9 pin male Serial COM2 RS422 485 isolated COM2 connector Sub D 9 pin female Number of USB A interfaces 2 USB A connector USB A host Number...

Page 19: ...e front side IP 65 Protect type back side IP 20 Dimensions Front panel 304 mm x 233 mm x 7 5 mm Rear panel 285 mm x 215 mm x 45 mm Installation cut out Width 287 mm Height 217 mm Minimum 1 5 mm Maximu...

Page 20: ...cabinet fronts the Touch Panel requires the following front plate cutting Touch Panel W x H in mm 62K JIDR 287 x 217 The fixing technique is integrated in the casing of the Touch Panel and accessible...

Page 21: ...rs to the CageClamps like this 1 Round opening for wires 2 Locking orange for screwdriver 3 Test point for 2mm test tip The picture on the left side shows the cabling step by step from top view 1 For...

Page 22: ...Touch Panel is provided by power supply the VIPA Startup Manager will be loaded At the first startup of the VIPA Startup Manager the following start screen appears n There is a button on the initial...

Page 23: ...the firmware images is shown which are available on the panel and connected storage media These images will be listed with create data and version number Choose your new image If the selected image is...

Page 24: ...owing batch files Start VIPA Webbrowser bat Start VIPA Webserver and Browser fullscreen bat Start VIPA Webserver and Browser bat Start VIPA Webserver bat n Under Delay Time you can adjust a delay time...

Page 25: ...Deployment RFID reader RFID Radio Frequency Identification is a technology that uses radio waves to automati cally identify objects and people An RFID system consists of an RFID transponder with an ac...

Page 26: ...ting time When the box with Enter default is activated after the ID a line break is dis played n Shared Memory VIPARFiD After reading the ID is written into the internal memory n Com Port Settings Via...

Page 27: ...the application courses in the PLC according to the configured processes Via dia logues configured before process values may be monitored graphically altered and eval uated 3 5 Operating system Windo...

Page 28: ...ping on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the dragging that selects the touched objects Characteristics with Windows Embe...

Page 29: ...your Touch Panel like e g applications system settings file browser etc 2 Open applications For every open application a button can be found in the task bar There is no button for minimizing The switc...

Page 30: ...allows you to select one of the available software keyboards At the moment the following standard keyboards are implemented At pushed Shift key At pushed a key Please note that can exclusively be ent...

Page 31: ...re keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides the keyboard aga...

Page 32: ...nment via DHCP n System properties System Here you receive information about the version of the current Windows operating system the memory load and sharing alterations here are not accepted into the...

Page 33: ...a mobile device and a PC via USB Many devel oper tools res SCADA project engineering tools use ActiveSync for the data transfer Before you can access the Touch Panel from the PC via ActiveSync you hav...

Page 34: ...ouch Panel The USB device Touch Panel is recognized and the dialog window new part nership opens 2 Choose yes for fixing a partnership and push Next 3 In the opening window de activate all synchroniza...

Page 35: ...ed in the description of the server A client is an application that uses the service of a server within a network For example a web browser is a client because at every call of a website it sends a re...

Page 36: ...on your Touch Panel 3 As soon as your Touch Panel is connected via Ethernet you may monitor the IP address data via in the taskbar 4 After you ve confirmed the pre settings start your ftp client e g W...

Page 37: ...elete and create files and directories You may also start applications Terminating an application is not possible The establishing of a Telnet connection is password protected and has the following ap...

Page 38: ...the VNC server is on delivery deactivated Due to software reasons VIPA does not support the VNC server function With Autostart you can select the automatic startup of the VNC server via the Startup M...

Page 39: ...sources in a Microsoft network like drives and printer Here you may assign existing public directories or printer in the network to local directories or printer in the Touch Panel Condition for this i...

Page 40: ...rname guest Input net use data testserver archiv user guest The connected network drive is then available via network data at the Touch Panel The configuration of a network printer happens with the fo...

Page 41: ...the network connection to the drive archive of test server To save the settings also after power on you have to store them to the registry with START Programs KuK_Tools KuK Tools Store Terminate netwo...

Page 42: ...fferent ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead fr...

Page 43: ...lkie n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following...

Page 44: ...special EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrica...

Page 45: ...ltage even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts h...

Page 46: ...e groups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installe...

Page 47: ...the equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is connec...

Page 48: ...the cover Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and t...

Page 49: ...Z diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutra...

Page 50: ...been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunc...