XK3190-A28E
- 10 -
6)
Display
【
End
】
Press “clear”, go back to weighing mode, the new calibration parameter are actived.
Continue keep pressing
【
Function
】
to adjust the other parameters .
2. Press
【
#
】
to enter into the calibration page while turning on the instrument.
quick zero calibration:
Any time before display
【
nOLOAD
】
,press
【
Function
】
to keep the invariability of parameter setting of the original
division value
、
decimal point
、
Max weigh, indicator enter to zero calibration state directly. When stabilization
indication light appear, press
【
zero
】
, display
【
End
】
, means to keep the parameter of the original full capacity
calibration, then press
【
clear
】
to save the parameter go back to weighing state.
Access to full capacity calibration state directly:
Any time before display
【
AdLOAD
】
, press
【
*
】
to keep the invariability of parameter setting of the original
division value
、
decimal point
、
Max weigh, keep the invariability of the original zero parameter, access to full
capacity calibration state directly.
Note: Switch off the calibration switch after the calibration, and seal it .
Chapter 5 User’s Function Setting
At weighing mode, keeping pressing [Func] for more than 5 seconds, it enters user functions setting mode P1~P8
(user can change it at any time)
、
F1~F8
(
protect by permission calibration switch
)
16 parameter setting, press [Tare]
to change the value, press [*] to choose the next parameter. Parameter description as follows:
1
、
P1 x
Baud rate setting
x=1:
9600
x=2:
4800
x=3:
2400
x=4:
1200
2
、
P2 x
RS232 output gross weight
、
net weight selection
x=1:
Net weight output
x=2:
Gross weight output
x=3:
tare output
3
、
P3 x
RS232 output mode selection
x=1:
No transmission (RS232 stop)
x=2:
Continuous transmission
x=3:
Continuous transmission only when stable
x=4:
Command mode
(
Z:zero
,
T:tare
,
R:send the weight date one time
)
x=5: A7 Continuous transmission
x=6:
save setting
4
、
P4 x
energy - saving
function setting
x=1:
turn off energy saving
x=2:
energy saving mode 1
,
about 30 seconds
x=3:
energy saving mode 2
,
about 60 seconds
x=4:
power saving mode 3
,
about 30 seconds
,
quit power saving state only by press key
x=5:
power saving mode 4
,
about 60seconds
,
quit power saving state only by press key
(
Note
:
It just can enter to power saving state under the condition of the gross weight as zero
)