background image

YZ-X2

14

3.4 Battery Maintenance

The power system of this washing machine is powered by two

12V maintenance-free lead-acid batteries in series, and the system

voltage is 24V.

●When the machine works for a period of time, the battery power

drops, and when the last bar of the power display meter is flashing,

it means that the power is insufficient and needs to be charged in

time;

●When maintaining the battery, please wear protective gloves to

avoid contact with the acid substance of the battery;

● Check whether the battery connecting wire is worn and the

contact parts are loose, and replace it if necessary;

●The terminal of the battery should be kept clean and dry, and

there should be no debris and dust covering it, which is extremely

unfavorable to the battery, and will burn the battery in severe

cases.

Step 1: Align the

holes of the front

rubber strip with the

protrusions of the

plastic assembly of

the squeegee;

Step 2: Fix the plastic

components on the

cast aluminum base

plate of the

squeegee;

Step 3: Align the

holes of the rear

rubber strip with the

plastic components of

the squeegee to the

protrusions;

Step 4: Use both ends

of the bead to snap

together;

Step 5: Tighten the

Nuts.

! ! Notice

In order to make the battery have a long service life, it should be charged in time

after the machine is finished, and deep discharge is strictly prohibited.

The correct charging method of the lead-acid battery: first insert the battery, then

plug in the mains; when fully charged, first cut off the mains, and then pull out the

battery plug.

If the machine is not used for a long time, please fully charge the battery, disconnect

the positive pole of the battery, and store it.

Summary of Contents for YZ-X2

Page 1: ...YZ X2 Floor Scrubber operation instructions ...

Page 2: ...YZ X2 Yangzi Make cleaning easier ...

Page 3: ...cautions for machine operation 10 Chapter 3 Routine Maintenance and Disassembly and Replacement of Wearing Parts 11 3 1 Periodic Inspection 11 3 2 Brush disk replacement installation and adjustment 12 3 3 Replacement and installation of the absorbent strip 13 3 4 Battery Maintenance 14 3 5 Maintenance and disassembly of suction motor 15 3 6 Fuse removal 16 3 7 Disassembly of the float cage 16 Chap...

Page 4: ...YZ X2 2 Warranty 19 ...

Page 5: ...rameters Category Maintenan ce free Liquid fil ling Type Wire drawing Type Cleaning efficiency 2800 h Brush width 18 inch Squeegee width 800 mm Brush speed 195 rpm Brush motor power 550 w Suction motor power 550 w Category Maintenan ce free Liquid fil ling Type Wire drawing Type Cleaning efficiency 50 L Brush width 50 L Squeegee width 24V 100Ah Brush speed 2 3h Brush motor power 151 kg 150 kg 111 ...

Page 6: ...tart switch to the off position and please remove the key from the main power switch The machine must be used by qualified and authorized personnel Children and disabled persons are not allowed to use the machine Keep the battery away from sparks flames and smoke Do not use it in a place where dangerous flammable or explosive gas liquid or water vapor is present This machine can clean general garb...

Page 7: ...er Confirming that the machine is in proper operation and safe condition professionals or service center must work in accordance with the maintenance section of this manual Even if the machine is to be dismantled and scrapped someone should be there to pay attention Because some harmful substances such as batteries waste oil etc have met the standards they should be sent to a specific center for p...

Page 8: ...be observed Even if you have used a similar sweeper before please read the instructions carefully Reading the instructions beforehand will save you a lot of time in the future It is vital that you become familiar with all accessories and controls and their functions before you start using them Read through this manual so you don t get scrambled when you turn it on Chapter 2 Use of the Machine 2 1 ...

Page 9: ...e with the needle plate and add a cleaning pad for cleaning which can effectively protect the ground The charging socket cable requires at least a power cable with a diameter of 4mm Note The charger is placed on a stable platform pay attention to moisture proof anti moisture Water and drop resistant The charging time must be guaranteed for 6 10 hours per charge Guaranteed electricity The battery i...

Page 10: ...serted into the suction port Step 1 Unscrew the water absorbing cross knob Pull the handle down and put down the water absorption swaying tail bracket Step 2 Thread the Absorbent Fixing Screw through the Tripod Step 3 Install the sewage suction pipe The squeegee has been debugged at the factory and can be used after installation Power display After turning on the main power switch the voltmeter wi...

Page 11: ...ndlebars and keep driving at a constant speed start the brush switch button and the water absorption motor switch button Stop of the machine Close the brush switch button first Close the drain valve Close the switch button of the water suction motor Turn off the main power switch Lightly step on the foot lever to lift the scrubber By pulling the handle lift the squeegee head ...

Page 12: ...revent the sewage from immersing in the suction motor and causing it to burn To clean the ground with serious oil pollution please put an appropriate amount of detergent into the clean water tank to achieve better cleaning effect and at the same time drop an appropriate amount of defoamer into the sewage tank to prevent the sewage tank foam from immersing in the suction motor and causing burns Aft...

Page 13: ...ect the positive and negative output wires of the battery and place the machine in a dry and clean place Chapter 3 Routine Maintenance and Disassembly and Replacement of Wearing Parts 3 1 Periodic Inspection Regular maintenance and inspection Intervals h 4 50 100 200 500 1 Battery level detection 2 Motor carbon brush inspection ...

Page 14: ...ure that the machine is in a power off state Lightly step on the foot lever to keep the brush disc lifted Facing the direction of the brush plate hold the brush rotate it to the right and the brush plate can be removed rotate it to the left to complete the installation Note When installing make sure the flange is aligned with the brush plate button holes Replacement of the dial The dial can be pur...

Page 15: ...be properly tightened Principle Dynamic Balance 3 3 Replacement and installation of the absorbent strip Place the machine on a flat ground turn off the main power switch and ensure that the machine is powered off Put down the squeegee through the handle after rotating the plastic handle in the opposite direction take out the squeegee assembly Unscrew the squeegee assembly nut remove the bottom pla...

Page 16: ...mely unfavorable to the battery and will burn the battery in severe cases Step 1 Align the holes of the front rubber strip with the protrusions of the plastic assembly of the squeegee Step 2 Fix the plastic components on the cast aluminum base plate of the squeegee Step 3 Align the holes of the rear rubber strip with the plastic components of the squeegee to the protrusions Step 4 Use both ends of...

Page 17: ...ntering the filter screen and into the suction motor causing the motor to burn Removal of suction motor The suction motor is fixed at the bottom of the clean water tank Before removing 1 First empty the machine with clean water turn off the main power switch and keep the machine powered off 2 Turn the clean water tank back and pull out the suction motor pair socket 3 Loosen the fixing nut of the s...

Page 18: ...rm the fuse model and replace the damaged fuse 3 7 Disassembly of the float cage In the daily use of the machine because the floating ball cage exists in the sewage tank and when the sewage is too full the floating ball will be sucked at the air outlet by the suction of the suction motor and the customer needs regular maintenance You can refer to the following steps to operate Before dismantling t...

Page 19: ...rvice center Fan not working Suction motor noise is too loud Please contact the service center Suction motor burned out Replace the suction motor Carbon brush wear Please contact the service center Little or no water flow out Clogged water tank drain valve or water pipe Clean or replace the solution tank drain valve Drain valve closed Open the drain valve Inefficient recycling of sewage Recovery t...

Page 20: ...se Ambient temperature 10 40 c The relative humidity of the air 5 70 No conductive dust no explosion hazard environment An environment that does not contain gases or vapors that corrode metals Indoor use ventilated non vibration environment front and rear space at least 300mm Maintenance schedule Maintenance operation On handover Every 10h Every 50h Every 100h Every 200h Every 500h Brush Disc Heig...

Page 21: ...e to weather or force majeure More than 1 year of warranty or more than 1500 hours of use Warranty card Warranty Conditions 1 Within the day when the user purchases this product the motor is guaranteed for one year more than 7 days from the date of purchase no replacement only warranty 2 Before using the equipment you must understand the instructions and safety instructions 3 Man made damage to th...

Page 22: ...le and repair by themselves will not be covered by the warranty if repair is required a cost will be charged 5 The buyer can go to the designated point of the seller for maintenance with the invoice or send the machine back to our company for repair return freight and insurance premiums are paid by themselves ...

Reviews: