YAMIT F700 Installation & Operation Manual Download Page 1

Sand Separator

Hydrocyclone & Sedimentation Tank

Installation & Operation Manual

m

ar

-21

Yamit Filtration & Water Treatment Ltd.

. PO Box 232, Moshav Tnuvot, 428300 Israel.  

Tel: +972-4-6220006 Fax: +972-4-6220042 e-mail: 

[email protected]

www.yamit-f.com

Summary of Contents for F700

Page 1: ...drocyclone Sedimentation Tank Installation Operation Manual mar 21 Yamit Filtration Water Treatment Ltd PO Box 232 Moshav Tnuvot 428300 Israel Tel 972 4 6220006 Fax 972 4 6220042 e mail yamit yamit f com www yamit f com ...

Page 2: ... BE USED WITHOUT WRITTEN PERMISSION FROM YAMIT FILTRATION 1 General Information Operation 3 2 Description 4 3 Technical Data 5 4 Initial Installation Operation 7 5 Sedimentation Tank 8 5 1 Flushing 8 5 2 Periodic Cleaning 8 5 3 Maintenance 8 6 IPB Spare Parts description 9 7 International Warranty 13 F700 ...

Page 3: ...etween hydrocyclone and the sedimentation tank Operation Water enters the hydrocyclone via the tangential inlet which creates a spiral flow along the walls of the filter The centrifugal force separates the Suspended solids and sand particles and pushes them towards the walls of the sand separator Those particles gravitate downwards and into the sedimentation tank while clean water moves upwards an...

Page 4: ...ownward in a spiral path into an underflow chamber sedimentation tank while clean liquid moves upwards to the center of the spiral towards the top outlet A specially designed rubber insert protects the neck of the Hydrocyclone from erosion and increases separation efficiency The Sedimentation Tank can be drained automatically with an automatic flushing kit an electric valve controller and small co...

Page 5: ...t be installed before the filters if pressure is not controlled Available sizes 3 4 6 8 12 16 20 24 and 30 End connections Thread TH Flange FL Groove GR Sedimentation Tank connections Thread 3 4 6 8 size Flange 12 16 20 24 and 30 size Groove 8 size F700 Model ØD1 in In out ØD in H in H1 in Shipping Weight lb Packaging Vol LxWxH ft Flow rate GPM Sedimentation tank lt F710 3 380 475 8 3 0 31x0 31x0 ...

Page 6: ...6 MESH 120 140 180 200 270 325 600 MICRON 130 105 90 75 53 44 25 Pressure loss at 130 micron Filtration Grade Conversion Table F700 ...

Page 7: ...arrows Install the manual ball valve to the flush port of the Sedimentation Tank Check that the actual flow rate through the Hydrocyclone is within the recommended range Inadequate flow rate will result in reduced performance If more than one Hydrocyclone is installed leave sufficient space between units to facilitate maintenance A quick acting pressure relief valve must be installed upstream of t...

Page 8: ...e located at the bottom of the Sedimentation Tank to release pressure and drain Take off the cover Remove all the sediments collected in the Sedimentation Tank Thoroughly rinse the inside of the empty Sedimentation Tank Replace the cover on the Sedimentation Tank so that the cover gasket fits over it Mount tightening bracket and tightening handle properly WARNING Do not tighten or open cover durin...

Page 9: ...9 6 Illustrated Parts Breakdown F700 ...

Page 10: ... P TIGHTENING BRACKET 8 F F100 400 4 6 F500 600 4 F710 001M FT001M 5320010400 P COVER 4 FOR F115 215 FT001 FT002 F720 001M F730 002M FT002M F755 030M FT030M 5320010801 P COVER 8 F140 240 340 FT030 F760 060F FT060F 5320010600 P SERVICE HOLE COVER 6 F610 660 FT060 F740 005M FT005M 5320200601 P COVER 6 F100 300 2 3 F605 FT05 10 150 300 F750 005M F750LF 010V FT010V F770 150F FT150F F775 150F F780 300F...

Page 11: ...02M F0730 4180056501 PLUG 1 2 BSP PLASTIC F740 005M F0740 4180076501 PLUG 3 4 BSP PLASTIC F750 005M F0750 F750LF 010V F0750VLF F755 030M F0755 F760 060F F0760 F770 150F F0770 F775 150F F0755 F780 300F F0780 12 F730 002M F0730 4170050300 ELBOW 1 2 BSP FM GALVANIZED F740 005M F0740 F750 005M F0750 F750LF 010V F0750VLF F755 030M F0755 F760 060F F0760 F770 150F F0770 F775 150F F0755 F780 300F F0780 13...

Page 12: ...TEEL INSERT 2 1 1 2 BSP F755 16 F750LF 010V F0750VLF 4150103000 01P QUICK COUPLING 3 MODEL 75 17 F760 060F FT060 5312007600 068 RUBBER BASE FOR LEG F530 550 620 630 18 F760 060F F0760 4102160301 070 BOLT HEX HEAD 5 8 NC 2 3 4 GALVANIZED F770 150F F0770 F775 150F F0775 F780 300F F0780 19 F760 060F F0760 4112160301 NUT 5 8 NC GALVANIZED F770 150F F0770 F775 150F F0775 F780 300F F0780 20 F760 060F F0...

Page 13: ... of any kind or nature regardless of the nature thereof including without limitation injury to persons or property loss of use of the products loss of goodwill loss of profits or any other contingent liabilities of any kind or character alleged to be the cause of loss or damage to the purchaser This warranty does not cover damage or failure caused by misuse abuse or negligence nor shall it apply t...