background image

YCO-1094-04-02

CPC-2000

                 Technical Manual

Table of Contents

SAFETY INSTRUCTIONS

I.      Introduction                                                                    1

II.     Setup                                                                               1

           Technician Setup Mode
           Setting the Keywords
           Calibrating the Scale

III.    Troubleshooting                                                             6

IV.    Wiring Diagram                                                              7

V.     Parts List                                                                        8

Before using the scale, carefully read, understand, and follow the “Safety Instructions” described in this manual.  Observe the advice given in 

the Operation Manual to ensure proper operation.  Keep this manual handy for reference. 

1)       This scale is 

not

 an explosion-proof model.  Do not use the scale in an atmosphere containing fl ammable gases or explosive fumes.  A fi re or an explosion can result.

2)       Do not operate the scale if there is smoke or a burnt smell coming from the scale.  Remove the batteries or unplug the AC adaptor immediately.  After making sure that there is no 

danger, consult your dealer.

  Never try to repair the scale by yourself.

3)       Never step on or sit on the scale.  Not only will the scale be damaged, but you may also be injured.
4)       Place the item to be weighed in the center of the platform.  Items placed on the edge of the platform may fall off and cause injury.
5)       When weighing a heavy, large or unbalanced item, make sure the item is stable on the platform, otherwise, an accident may occur.
6)       When carrying or moving the scale, be sure to hold it by the bottom of the base with both hands.  If you hold it by the platform, the platform may become detached causing the scale to 

fall.  This will damage the scale.  The platform is designed for easy removal and clean-up.

7)       Do not insert your fi nger into the gap or holes in the scale.  You may be injured.

To prevent damage to the scale

1)       Do not push the indicator or keys with sharp objects.  They may break or puncture the switch membrane panel.
2)       Use the specifi ed power supply and choose a suitable environment.  If you do not, the weight readings may be inaccurate and the scale may be damaged.
3)       The scale is a sensitive weighing instrument, avoid physical shocks.  If you drop something on the scale, step on the platform, or drop it, the scale may be damaged and lose accuracy.
4)       If the scale becomes dirty, wipe it with a soft cloth.  For stubborn stains, apply a little neutral detergent and then wipe the scale with a dry cloth.  Do not use thinner, benzene, hot water, 

or chemical agents on non-metallic parts, all of which can cause deformation, discoloration, or deterioration.

5)       Never remove the case.  The fi ne adjustment section may be damaged and you may be injured by sharp edges on the internal parts.
6)       Do not place the scale upside down.
7)       When the low battery indicator appears, recharge the battery.  The battery should only be replaced by a qualifi ed scale technician.  If the scale will not be used for a long period, have 

the battery removed.

To keep the scale working effi ciently

1)       Place the scale on a fl at stable surface that will support the scale and the load.
2)       Do not place the scale in an area exposed to direct sunlight or to wind currents from an air conditioner, otherwise, the weights will not be accurate.
3)       Do not place the scale near machines that create vibrations or electromagnetic disturbance, such as microwave ovens, portable phones, or large motors.  This will affect the accuracy.
4)       The operating temperature range is from –10°C to +40°C (14°F to 104°F).  Do not subject the scale to sudden temperature changes; allow the scale to adjust to the new temperature 

before use.

5)       This scale is not waterproof or dustproof.  Do not expose the scale to splashing water.  Do not install the scale in an extremely humid or dusty environment.
6)       If the scale is sealed, do not break the seal.  If you break the seal, the scale will not be considered legal for trade.  In this case, contact your dealer.  
7)       Do not disassemble or modify the scale, you will void the warranty.  Modifi ed scales will not be legal for trade.

Summary of Contents for CPC-2000

Page 1: ...04 02 YAMATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 www yamatocorp com ...

Page 2: ...t If you do not the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the platform or drop it the scale may be damaged and lose accuracy 4 If the scale becomes dirty wipe it with a soft cloth For stubborn stains apply a little neutral detergent and then wipe the scale with a...

Page 3: ...ale after two three four or five minutes of non use unless the feature is disabled The time delay for the automatic off including full dis able is set in the technician set up mode see section II Capacity Increment Accuracy Maximum Tare 2 kg 0 001 kg 0 001 kg 2 kg 5 lb 0 05 oz 0 05 oz 5 lb 4 lb 0 002 lb 0 002 lb 4 lb 80 oz 0 05 oz 0 05 oz 80 oz Capacity Increment Accuracy Maximum Tare 4 kg 0 002 kg...

Page 4: ...hnician setup mode at any time by pressing the ON OFF key for about five seconds After exiting the technician setup mode remove the platform from the load cell assembly return the up per housing to the original position taking care not to pinch the wiring between the upper and lower housing Do not allow the wiring to rub against the upper load cell assembly Replace the four up per housing screws an...

Page 5: ...T or TOGGLE key Refer to the setup chart on the following page Any unit that is se lected ON will be displayed in sequence during normal operation when the UNIT key is pressed Mixed units such as the combined pound and ounce are not allowed on legal for trade scales under NTEP regulations If your scale is to be used as a legal for trade scale the lb oz mode must be disabled The auto off setting se...

Page 6: ...unctions 4 TARE UNIT UNIT UNIT UNIT N G N G UNIT UNIT UNIT UNIT UNIT UNIT UNIT Press for three seconds UNIT N G Enter the calibration program UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT N G N G N G N G kg lb oz lb oz N G N G UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT N G ...

Page 7: ...unts Press the UNIT key to select either pound or kilogram calibration weights With an empty platform on the load cell assembly press the TARE key The scale should read 0 If 0 is not displayed then press the TARE key again until 0 is displayed Place either 2 kg or 5 lb depending on the units selected above on the scale platform Wait for the counts to stabilize and press the TARE key again The scal...

Page 8: ...ecessary If no weight is on the platform calibration or service is required Power on counts are less than calibrated zero minus 10 This generally indicates that the platform is not on the scale or that something is wedged between the platform and the scale body Replace the scale platform remove any obstruc tions under the platform and press the ON OFF key if neces sary Otherwise calibration or ser...

Page 9: ...YCO 1094 04 02 CPC 2000 Technical Manual IV Wiring Diagram 7 LED MAIN BOARD KEYPAD BAT DC JACK RED BLUE WHITE GREEN BLACK RED RECHARGEABLE BATTERY 6 V 4Ah LOAD CELL POWER BOARD DC JACK E E S S ...

Page 10: ...YCO 1094 04 02 CPC 2000 Technical Manual V Parts List 8 ...

Page 11: ... 7 CHA 1595 000070 Load Cell Assembly 4 lb 2 kg 1 CHA 1595 000080 Load Cell Assembly 10 lb 4 kg 1 8 CHA 1595 000090 Wire Clip 1 9 CHA 1595 000100 Hex Screw M3 x 6 1 10 CHA 1595 000110 Rubber Pad 4 11 CHA 1595 000120 Hex Nut M4 2 12 CHA 1595 000130 Power Board 1 13 CHA 1595 000140 Stainless Steel Upper Housing 1 14 CHA 1595 000150 Holder Bubble Level 1 15 CHA 1595 000160 Bubble Level 1 16 CHA 1595 ...

Reviews: