4. Operation

Functional check and setting

SET:

  Gently rotate the setting knob to the RESET side 

until it stops. The detector is now set and the 

display window turns green.

TEST:

  Rotate the set dial to the TEST side to activate the 

detector, and the display window turns red. Check 

that the electrical contacts are operating correctly. 

After testing by turning the knob between RESET and 

TEST two or three times, turn it to RESET to begin 

operation. 

S

E

R ET

E

T

S T

RESET

TEST

5. Maintenance

 CAUTION

In conjunction with the periodic inspection of 

• 

equipment or machinery, do a functional check at least 

once a year, and a Gal response level check at least 

once every three years.

Replace the detector if any abnormality is found in the 

• 

functional or Gal checks.

Before transporting, be sure to fasten the locking 

• 

screw. Otherwise vibration or shock may damage the 

detector.

Gal response level check

Remove the side panel.

1. 

Loosen the level adjustment nut sufficiently so that the 

2. 

base can be moved left and right, and remove the two 

level adjustment screws.

Using the level adjustment nut as the axis of rotation, 

3. 

gently rotate the base clockwise and note the pointer 

indication on the scale when the device is activated. 

Repeat this procedure two or three times, and check that 

the average reading falls within the red region of the 

scale.

  Handling Precautions

In this procedure, slight variations in the reading 

may occur according to the adjustment of the 

level at the time of installation and the zero 

adjustments for the scale plate, in addition to the 

way in which the base is rotated.

After the inspection has been completed, return the 

4. 

detector to its former state, and fasten securely.

10

20

0

10

20

0

Red region 

6. Specifications

Item

Specification

General

Name

Seismic detector

Detection 

method

Magnetic

External 

dimensions

147×163×102.5 mm (W×H×D) 

Mass

Approx. 1.6 kg

Color

Blue

Mounting

Indoor, on firm wall or pillar surface (level 

for vertical mounting is provided).

Retaining screws: M6 (4)

Mounting pitch: 130×130 mm

Terminal box M3.5 terminal screws
Conduit 

Dia. 15 mm, grommet with membrane

Allowable 

temperature

-10 to +50 °C (no high humidity or 

corrosive environments)

Performance

Sensing 

direction

Horizontal and vertical

Operation 

indication

By change of color in indication window: 

green for Run (reset), red for Stop 

(tripped out)

Setting

Set manually with setting knob

Operation 

check

Manual

Acceleration 

setting check

Gal response level check by tilting the 

detector

Electrical

Contact form SPDT (single pole double throw)
Contact rating 125/250 Vac, 10 A with resistive load, 2 A 

with motor load (power factor 0.4)

Contact 

material

Silver alloy

Insulation 

resistance

100 MΩ or more (500 Vdc megger)

Dielectric 

strength

1500 Vac, 1 min

Summary of Contents for VBC7000 Series

Page 1: ...manual before using this device Improper use could result in damage to the device or equipment and may cause bodily injury Do not install the device in places below Faulty operation fire or explosion could result On a steep incline In a place that is normally subject to vibration or that receives shock from an opening and shutting door etc Where the temperature or humidity is high Where there is w...

Page 2: ...of the mounting holes using this line as a datum Attach the detector firmly using four M6 screws in the 2 four mounting holes After loosening the two level adjustment screws and the 3 level adjustment nut move the base back and forth and around so that the ball chain is not in contact with the perimeter of the level hole and then fasten the screws and nut temporarily Adjust the base carefully so t...

Page 3: ...eck that the average reading falls within the red region of the scale Handling Precautions In this procedure slight variations in the reading may occur according to the adjustment of the level at the time of installation and the zero adjustments for the scale plate in addition to the way in which the base is rotated After the inspection has been completed return the 4 detector to its former state ...

Page 4: ...cy Hz VBC7000 series models Unit Gal Model number Acceleration setting VBC7000 012 12 7 VBC7000 015 15 10 VBC7000 020 20 14 VBC7000 025 25 15 VBC7000 030 30 15 VBC7000 040 40 16 VBC7000 060 60 18 VBC7000 080 80 20 VBC7000 100 100 22 VBC7000 120 120 24 VBC7000 135 135 26 VBC7000 150 150 27 VBC7000 200 200 32 VBC7000 225 225 35 VBC7000 250 250 37 Advanced Automation Company 1 12 2 Kawana Fujisawa Ka...

Reviews: