![Yamatake SDC35 User Manual Download Page 25](http://html.mh-extra.com/html/yamatake/sdc35/sdc35_user-manual_905228025.webp)
Chapter 1.
OVERVIEW
1 - 1
Overview
1-1
This unit is a compact controller having a mask of 48
X
96 mm or 96
X
96 mm and provides the following
features:
• The depth is only 65 mm, providing excellent space-saving.
• The front panel is only 5 mm thick. This ensures excellent thin design.
• The display panel is large. This provides excellent visibility.
•
[mode]
key,
[para]
key, digit-shift keys,
[display]
key, and
[enter]
key are
provided on the front panel. This ensures easy setup operation.
• Various input types are available, thermocouples (K, J, E, T, R, S, B, N, PLII,
WRe5-26, Ni-NiMo, PR40-20, DIN U, DIN L, gold iron chromel), RTDs
(Pt100, JPt100), current signals (4 to 20mAdc, 0 to 20mAdc), and voltage
signals (0 to 10mVdc, -10 to +10mVdc, 0 to 1Vdc, 1 to 5Vdc, 0 to 5Vdc, and 0
to 10Vdc).
• The accuracy is ±0.1%FS and the sampling cycle time is 0.1 sec. This ensures
high accuracy.
• For control output types, relay, voltage pulse for driving SSR, current output,
and continuous voltage outputs are provided. Additionally, these control output
types can be combined for control outputs 1 and 2.
• Three event output points or two event output points (independent contacts) are
provided as standard functions.
• 2-point CT input, 4-point digital input, RSP input, and RS-485 can be combined
as optional functions.
• Current output or continuous voltage output is provided as auxiliary output.
• The unit can be configured for the heat/cool control using the 2nd control
output and/or event relay.
• The unit can be controlled by means of the ON/OFF control or fixed PID
control method.
• In addition to the PID control, two algorithms, RationaLOOP and Just-FiTTER,
are built-in, which ensures excellent controllability.
• The personal computer loader port is provided as standard function. The setup
can be configured easily with use of the personal computer loader.
• Use of optional the
SLP-C35
Smart Loader Package makes it possible to easily
perform the read/write operation of the parameters.
In addition to the table format setup, the operation and control status can be
monitored using the trend display. This unit can be operated without use of
program on the host unit.
• The unit conforms to the IEC directive and the CE marking is affixed on the
unit.
(Standards compliance: EN61010-1 and EN61326)
Summary of Contents for SDC35
Page 16: ......
Page 17: ......
Page 19: ... display key para key or V key key enter key 2 second press hold of para key V ...
Page 32: ......
Page 46: ......
Page 58: ......
Page 71: ......
Page 84: ......
Page 95: ......
Page 172: ......
Page 174: ...6 2 Chapter 6 LIST OF DISPLAYS AND SETTING DATA ...
Page 211: ......
Page 230: ......
Page 240: ......
Page 248: ......
Page 260: ......
Page 268: ......
Page 270: ......
Page 279: ......