To drain water from the bilge:
(1) Remove the stern drain plugs.
(2) Raise the bow of the watercraft until the
water drains.
(3) After the water has drained, wipe the
bilge with dry rags to make sure that it is
thoroughly dry.
(4) Install the stern drain plugs.
CAUTION:
ECJ00360
●
Before installing the stern drain plugs,
clean the drain plug threads to remove
any foreign materials, such as dirt or
sand. Otherwise, the stern drain plugs
could be damaged, allowing water to en-
ter the engine compartment.
●
Make sure that the stern drain plugs are
tightened securely before launching the
watercraft. Otherwise, water may flood
the engine compartment and cause the
watercraft to submerge.
EJU32470
Stern drain plugs
Check the stern drain plugs for proper instal-
lation.
CAUTION:
ECJ00360
●
Before installing the stern drain plugs,
clean the drain plug threads to remove
any foreign materials, such as dirt or
sand. Otherwise, the stern drain plugs
could be damaged, allowing water to en-
ter the engine compartment.
●
Make sure that the stern drain plugs are
tightened securely before launching the
watercraft. Otherwise, water may flood
the engine compartment and cause the
watercraft to submerge.
EJU32480
Battery
Check the battery condition and the electro-
lyte level.
Check that the battery leads are tightened se-
curely and that there is no corrosion on the
battery terminals.
WARNING
EWJ00450
●
The battery must always be fully
charged and in good condition. Loss of
battery power may leave you stranded.
Never operate the watercraft if the bat-
tery does not have sufficient power to
start the engine or if it shows any other
signs of decreased power.
●
Be sure to connect the breather hose to
the battery. Fire or explosion could re-
sult if the breather hose is damaged, ob-
structed, or not connected properly.
1
Positive (+) battery terminal: Red lead
2
Negative (–) battery terminal: Black lead
3
Breather hose
UF1K72E0.book Page 47 Wednesday, August 2, 2006 10:43 AM