–37–
HEAT EXCHANGER
COOL
1
2
COOLING SYSTEM
HEAT EXCHANGER
1. Measure:
S
Filler cap opening pressure
Cap opens at pressure below the speci-
fied pressure
!
Replace.
Cap opening pressure:
95
X
125 kPa
(0.95
X
1.25 kg / cm
2
,
13.58
X
17.87 psi)
Measurement steps:
D
Attach the cooling system tester
(90890-01325, YU-24460-01) to the
coolant filler cap
.
D
Apply the specified pressure for 10
seconds, and make sure there is no
pressure drop.