17
EFFECT PARAMETER LIST
* Use the “Effect Data Value Assign Tables” listed in the “See Table” column for relations of “data” and actual
parameter values.
* Parameters marked with a “
●
” in the “Control” column can be controlled by an assignable controller.
1
Reverb Time
0.3~30.0s
0-69
table#4
2
Diffusion
0~10
0-10
3
Initial Delay
0~63
0-63
table#5
4
HPF Cutoff
Thru~8.0kHz
0-52
table#3
5
LPF Cutoff
1.0k~Thru
34-60
table#3
6
Width
0.5~10.2m
0-37
table#11
7
Heigt
0.5~20.2m
0-73
table#11
8
Depth
0.5~30.2m
0-104
table#11
9
Wall Vary
0~30
0-30
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
Rev Delay
0~63
0-63
table#5
12
Density
0~4
0-4
13
Er/ Rev Balance
E63> R~ E=R ~ E<R63
1-127
14
High Damp
0.1~1.0
1-10
15
Feedback Level
-63~+63
1-127
16
No. Parameter
Display
Value
See Table Control
WHITE ROOM, TUNNEL, CANYON, BASEMENT
1
Lch Delay1
0.1~355.0ms
1-3550
2
Lch Feedback Level
-63~+63
1-127
3
Rch Delay1
0.1~355.0ms
1-3550
4
Rch Feedback Level
-63~+63
1-127
5
High Damp
0.1~1.0
1-10
6
Lch Delay2
0.1~355.0ms
1-3550
7
Rch Delay2
0.1~355.0ms
1-3550
8
Delay2 Level
0~127
0-127
9
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
HPF Cutoff
Thru~8.0kHz
0-52
table#3
12
LPF Cutoff
1.0k~Thru
34-60
table#3
13
14
15
16
No. Parameter
Display
Value
See Table Control
ECHO
1
Type
S-H, L-H, Rdm, Rvs, Plt, Spr
0-5
2
Room Size
0.1~7.0
0-44
table#6
3
Diffusion
0~10
0-10
4
Initial Delay
0~63
0-63
table#5
5
Feedback Level
-63~+63
1-127
6
HPF Cutoff
Thru~8.0kHz
0-52
7
LPF Cutoff
1.0k~Thru
34-60
8
9
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
Liveness
0~10
0-10
12
Density
0~3
0-3
13
High Damp
0.1~1.0
1-10
14
15
16
No. Parameter
Display
Value
See Table Control
EARLY REF1, EARLY REF2
1
L->R Delay
0.1~355.0ms
1-3550
2
R->L Delay
0.1~355.0ms
1-3550
3
Feedback Level
-63~+63
1-127
4
Input Select
L,R,L&R
0-2
5
High Damp
0.1~1.0
1-10
6
7
8
9
10
Dry/Wet
D63>W ~ D=W - D<W63
1-127
●
11
HPF Cutoff
Thru~8.0kHz
0-52
table#3
12
LPF Cutoff
1.0k~Thru
34-60
table#3
13
14
15
16
No. Parameter
Display
Value
See Table Control
CROSS DELAY
1
Type
TypeA,TypeB
0-1
2
Room Size
0.1~7.0
0-44
table#6
3
Diffusion
0~10
0-10
4
Initial Delay
0~63
0-63
table#5
5
Feedback Level
-63~+63
1-127
6
HPF Cutoff
Thru~8.0kHz
0-52
table#3
7
LPF Cutoff
1.0k~Thru
34-60
table#3
8
9
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
Liveness
0~10
0-10
12
Density
0~3
0-3
13
High Damp
0.1~1.0
1-10
14
15
16
No. Parameter
Display
Value
See Table Control
GATE REVERB, REVERSE GATE
1
Lch Delay
0.1~715.0ms
1-7150
2
Rch Delay
0.1~715.0ms
1-7150
3
Feedback Delay 1
0.1~715.0ms
1-7150
4
Feedback Delay 2
0.1~715.0ms
1-7150
5
Feedback Level
-63~+63
1-127
6
High Damp
0.1~1.0
1-10
7
8
9
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
HPF Cutoff
Thru~8.0kHz
0-52
table#3
12
LPF Cutoff
1.0k~Thru
34-60
table#3
13
14
15
16
No. Parameter
Display
Value
See Table Control
DELAY L,R
1
Lch Delay
0.1~715.0ms
1-7150
2
Rch Delay
0.1~715.0ms
1-7150
3
Cch Delay
0.1~715.0ms
1-7150
4
Feedback Delay
0.1~715.0ms
1-7150
5
Feedback Level
-63~+63
1-127
6
Cch Level
0~127
0-127
7
High Damp
0.1~1.0
1-10
8
9
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
HPF Cutoff
Thru~8.0kHz
0-52
table#3
12
LPF Cutoff
1.0k~Thru
34-60
table#3
13
14
15
16
No. Parameter
Display
Value
See Table Control
DELAY L,C,R
1
Reverb Time
0.3~30.0s
0-69
table#4
2
Diffusion
0~10
0-10
3
Initial Delay
0~63
0-63
table#5
4
HPF Cutoff
Thru~8.0kHz
0-52
table#3
5
LPF Cutoff
1.0k~Thru
34-60
table#3
6
7
8
9
10
Dry/Wet
D63>W ~ D=W ~ D<W63
1-127
●
11
Rev Delay
0~63
0-63
table#5
12
Density
0~4
0-4
13
Er/ Rev Balance
E63> R~ E=R ~ E<R63
1-127
14
High Damp
0.1~1.0
1-10
15
16
No. Parameter
Display
Value
See Table Control
HALL1, HALL2, ROOM1, ROOM2, ROOM3, STAGE1, STAGE2, PLATE