4
I/
o
signal functions
4-5
1.4 EtherNet/IP type
Operates as slave stations (adapters), with each unit occupying 6 input and 6 output channels.
n
NOTE
IP address setting is required in order for TS series to be properly recognized as a slave station in the EtherNet/IP
system. This setting can be specified from the support software (TS-Manager), or from the HT1.
(For the setting procedure, see section 5.3 "Setting Option parameters" in HT1 Operation Guide.)
Remote I/O (bit I/O)
n
Inputs (Master
Remote)
Output (Remote
Master)
Channel No.
Signal Name
Description
Channel No.
Signal Name
Description
m
bit0
PIN0
Point No. selection
n
bit0
POUT0
Point No. output
bit1
PIN1
bit1
POUT1
bit2
PIN2
bit2
POUT2
bit3
PIN3
bit3
POUT3
bit4
PIN4
bit4
POUT4
bit5
PIN5
bit5
POUT5
bit6
PIN6
bit6
POUT6
bit7
PIN7
bit7
POUT7
bit8
JOG+
Jog movement (+direction)
bit8
OUT0
Control output
bit9
JOG-
Jog movement (-direction)
bit9
OUT1
bit10
MANUAL
Manual mode
bit10
OUT2
bit11
ORG
Return-to-origin
bit11
OUT3
bit12
/LOCK
Interlock
bit12
BUSY
Operation-in-progress
bit13
START
Start
bit13
END
Operation-end
bit14
RESET
Reset
bit14
/ALM
Alarm
bit15
SERVO
Servo ON
bit15
SRV-S
Servo status
m+1
bit0
-
-
n+1
bit0
-
-
bit1
-
-
bit1
-
-
bit2
-
-
bit2
-
-
bit3
-
-
bit3
-
-
bit4
-
-
bit4
-
-
bit5
-
-
bit5
-
-
bit6
-
-
bit6
-
-
bit7
-
-
bit7
-
-
bit8
-
-
bit8
-
-
bit9
-
-
bit9
-
-
bit10
-
-
bit10
-
-
bit11
-
-
bit11
-
-
bit12
-
-
bit12
-
-
bit13
-
-
bit13
-
-
bit14
-
-
bit14
-
-
bit15
-
-
bit15
-
-
"m", "n": These values are determined in accordance with the channel setting.
Remote registers (word I/O)
n
Remote commands can be executed by using the 4-word input and 4-word output areas.
Inputs (Master
Remote)
Output (Remote
Master)
Channel No.
Signal Name
Description
Channel No.
Signal Name
Description
m+2
WIN0
Execution command
n+2
WOUT0
Status
m+3
WIN1
Command option
n+3
WOUT1
Command response
m+4
WIN2
n+4
WOUT2
m+5
WIN3
n+5
WOUT3