4
I/
o
signal functions
4-1
1. I/O specifications
The TS series allows positioning and push operations to be controlled from a host unit such as a PLC, etc., by
way of an I/O interface. The I/O specifications for the I/O interface are shown below. (Selected at the time
of purchase.)
I/O Specification
Explanation
Parallel I/O
NPN
16 input points, 24VDC ± 10%, 5.1mA/point, plus common
16 output points, 24VDC ± 10%, 50mA/point, sync type
PNP
16 input points, 24VDC ± 10%, 5.5mA/point, minus common
16 output points, 24VDC ± 10%, 50mA/point, source type
Serial I/O
CC-Link
CC-Link Ver.1.10 compatible, remote device station (1 station)
DeviceNet
Number of channels occupied by DeviceNet slaves: Inputs: 6CH; Outputs: 6CH.
EtherNet/IP
Number of channels occupied by EtherNet/IP slaves: Inputs: 6CH; Outputs: 6CH.
1.1 NPN and PNP type
Both the NPN and PNP types have 16 input points and 16 output points.
I/O signal table
n
No.
Signal Name
Description
No.
Signal Name
Description
A1
+COM
I/O power input, positive
common (24VDC ±10%)
B1
POUT0
Outputs
Point No. outputs
A2
B2
POUT1
A3
NC
No connection
B3
POUT2
A4
NC
B4
POUT3
A5
PIN0
Inputs
Point No. select
B5
POUT4
A6
PIN1
B6
POUT5
A7
PIN2
B7
POUT6
A8
PIN3
B8
POUT7
A9
PIN4
B9
OUT0
Control outputs
A10
PIN5
B10
OUT1
A11
PIN6
B11
OUT2
A12
PIN7
B12
OUT3
A13
JOG+
JOG movement (+ direction)
B13
BUSY
Operation-in-progress
A14
JOG-
JOG movement (- direction)
B14
END
Operation-end
A15
MANUAL
MANUAL mode
B15
/ALM
Alarm
A16
ORG
Return-to-origin
B16
SRV-S
Servo status
A17
/LOCK
Interlock
B17
NC
No connection
A18
START
Start
B18
NC
A19
RESET
Reset
B19
-COM
I/O power input, negative
common (0V)
A20
SERVO
Servo ON
B20