3
Data setting
3-10
• Speed switch
No.
Name
Setting / Setting Range
Units
Default
Restart
17
Speed switch
function
0: Disable 1: Enable
-
0
-
18
Switched speed
1 to 100
%
10
-
• Limitless rotation function
No.
Name
Setting / Setting Range
Units
Default
Restart
19
Limitless rotation
function
0: Disable
1: Enable
2: Enable (shorter rotation)
-
0
-
4.1.2 I/O parameters
• Terminal assignment
No.
Name
Setting / Setting Range
Units
Default
Restart
21
OUT0 select
0: No output
1: PZONE
2: NEAR
3: TLM-S
4: ORG-S
5: ZONE
6. MOVE
7: /WARN
8: MANU-S
-
1
Required
22
OUT1 select
-
2
Required
23
OUT2 select
-
3
Required
24
OUT3 select
-
4
Required
25
POUT select
0: None
1: At positioning completion (AFTER)
2: At positioning start (WITH)
-
1
Required
• Function selection
No.
Name
Setting / Setting Range
Units
Default
Restart
30
Alarm No. output
function
0: Disable 1: Enable
-
0
-
31
SERVO sequence
0: Edge 1: Level
-
0
-
32
JOG response time
0: JOG movement only
1 to 1000: Inching at leading edge, with JOG movement
after specified time elapses.
ms
0
-
33
Input filter
1 to 10
ms
2
-
• Communication
No.
Name
Setting / Setting Range
Units
Default
Restart
38
Node (controller)
1 to 16
-
1
-
4.1.3 Option parameters
• I/O function
No.
Name
Setting / Setting Range
Units
Default
Restart
80
Option enable
0: Disable 1: Enable
-
1
-
• CC-Link
No.
Name
Setting / Setting Range
Units
Default
Restart
81
Node
1 to 64
-
1
Required
82
Transmission rate
0: 156Kbps 3: 5Mbps
1: 625Kbps 4: 10Mbps
2: 2.5Mbps
-
4
Required
• DeviceNet
No.
Name
Setting / Setting Range
Units
Default
Restart
81
Node
0 to 63
-
0
Required
82
Transmission rate
0: 125Kbps
1: 250Kbps
2: 500Kbps
-
2
Required
• EtherNet/IP
No.
Name
Setting / Setting Range
Units
Default
Restart
81
Port number
0 to 65535
-
0
Required
-
IP address
0.0.0.0 to 255.255.255.255
-
192.168.0.1
Required
-
Subnet mask
0.0.0.0 to 255.255.255.255
-
255.255.255.0
Required
-
Default gateway
0.0.0.0 to 255.255.255.255
-
192.168.0.254
Required