2
Installation and wiring
2-7
3.2 Power supply connection
TS-X
TS-P
Use the power connector supplied with the controller to connect the power supply.
Power supply connector terminal names and functions
n
Power supply connector (TS-X 205, 210, 220 TS-P 205, 210, 220 200VAC specs.)
Signal Name
Description
L
Main power input
200 to 230VAC ±10%, 50/60Hz
N
L1
Control power input
200 to 230VAC ±10%, 50/60Hz
Consumption current
150mA MAX
N1
Power supply connector (TS-X 105, 110 TS-P 105, 110 100VAC specs.)
Signal Name
Description
L
Main power input
100 to 115VAC ±10%, 50/60Hz
N
NC
No connection
L1
Control power input
100 to 115VAC ±10%, 50/60Hz
Consumption current
300mA MAX
N1
Power supply connection examples
n
For 200VAC power supply:
AC IN
L
N
L1
N1
Wiring breaker
Controller
200VAC
Noise filter
Surge
absorber
Electromagnetic
contactor
23202-M1-00
L1
N1
AC IN
L
N
NC
For 100VAC power supply:
Wiring breaker
100VAC
Noise filter
Electromagnetic
contactor
Surge
absorber
Controller
23203-M1-00
c
CAutIoN
• Be sure that the power supply voltage and the terminal connections are correct. Incorrect voltage and
connections could cause an equipment failure.
• Shut the control power off while in a "servo off" condition.