A
ht
1
o
peration Guide
A-36
7.7 Alarm record display
1
On the main menu screen, select
"Monitor".
The "Monitor" menu screen opens showing
selectable menu items.
2
Move the cursor to "Alarm records"
and press
.
The "Alarm records" screen opens showing
up to 50 past alarms that occurred.
Pressing
or
moves the cursor up or
down. Pressing
or
switches the page.
I/O monitor
Status monitor
Run monitor
Alarm
Warning
Message
Alarm records
Monitor
NRM
[01]
Alarm records
No.
01:
02:
03:
04:
05:
06:
07:
08:
factor
86 OVERHEAT
85 OVERVOLTAGE
88 LOW VOLTAGE
85 OVERVOLTAGE
89 POSITION ERROR
82 ENCODER ERROR
86 OVERHEAT
81 AC POWER DOWN
NRM
[01]
"Alarm records" screen
Step 2
24A45-M0-00
3
To view the details of an alarm,
move the cursor to it and press
.
The screen shows the date when the alarm
occurred, as well as operating conditions.
On this screen, pressing
displays the
second page. Pressing.
returns to the first
page.
Alarm records
86
12:15:34
356.12
3.21
ABS
25
50
280.0
-
d:h:m
mm
mm/s
-
-
%
V
No.01
Factor
Time
Position
Speed
Run status
Run point
Current value
Voltage
NRM
[01]
Alarm record details screen
Step 3
24A46-M0-00
4
Press
CLR
to return to the "Alarm
records" screen.
Pressing
CLR
once more returns to the
"Monitor" menu screen.
c
CAutIoN
the alarm records are important data used to
analyze problems that occurred in this product, so
do Not delete them. leaving the alarm records
undeleted will cause no problems. however, if you
want to delete them, use the procedure below.
n
To delete the alarm records:
1.On the "Alarm records" screen, press
FUNC
.
2.When the "Function" menu appears showing "Delete all", press
.
3.When a confirmation message appears, select "Yes" and press
.