RS7000
66
ERROR MESSAGE
Operational Errors
System Errors
No Data
When a job is executed, the selected track or range contains no data. Select an
appropriate track or range.
Illegal Input
An unacceptable input or value has been specified. Check the input method or
value.
Illegal Track Number
An unacceptable track number has been specified. Select the track again.
Illegal Phrase Number
An unacceptable phrase number has been specified. Select the phrase again.
Illegal Measure
An unacceptable measure number has been specified. Select the measure
again.
Illegal Check Box
No check boxes have been checked in a track job which requires a check box
selection. Check the appropriate check box.
Meter Mismatch
The meter values of the original and edited data are different.
No F7 (End Of Exc.)
Exclusive data has been entered or changed without the necessary “End Of
Exclusive” byte (F7). Make sure F7 is included.
Preset Phrase
You have attempted to edit or record a preset phrase. Preset phrases must be
copied to a user phrase before they can be edited.
Pattern Length Mismatch
A job will result in the length of a phrase being greater than 256 measures.
Phrase Length Mismatch
An edit operation will result in a phrase which is longer than 256 measures.
Phrase Number Overflow
The maximum number of phrases (256) has been exceeded when recording,
executing a job, or editing.
Too Long Sample
A sample time stretch or other job has resulted in a sample being too long.
Too Short Sample
The sample length is too short and the Frequency Convert job cannot be exe-
cuted.
Too Low Freq
The sampling frequency is too low and the Frequency Convert job cannot be
executed.
Digital In Unlocked
The DIGITAL/OPTICAL input is unlocked. Check the connections and the out-
put from the source device.
Backup Battery Low
The internal backup battery is running low.
Sequence Memory Full
The internal memory is full and recording, editing, job execution, MIDI recep-
tion/transmission, or loading from card or disk cannot continue. Try again after
erasing unwanted song, pattern, or user phrase data.
Sample Number Overflow
A sampling operation, job, or load operation has exceeded the maximum
allowable number of samples. Try again after erasing unnecessary samples.
Too Many Local Voices
The maximum number of samples allowable for a pattern or song (128) has
been exceeded.
Too Many Common Voices
The maximum allowable number of common sample voices (128) has been
exceeded.
Too Many Sample Voices
The maximum overall number of sample voices (256) has been exceeded.
Wave Memory Full
The wave memory is full and further sampling operations, jobs, or load opera-
tions cannot be executed. In some cases, the amount of remaining memory will
be increased when you execute the Wave Memory Optimize operation.
Factory Set
This message appears when the RS7000 is restored to the initial factory set-
tings. The data in internal memory can be corrupted when the backup battery
voltage runs too low, for example, and all data will automatically be restored
to the factory settings, causing this message to appear.
Summary of Contents for RS7000 Ver.1.2
Page 6: ...RS7000 6 ...
Page 7: ...RS7000 7 ...
Page 38: ...RS7000 38 B B DM Circuit Board 2NA V615480 2 4 ...
Page 39: ...RS7000 39 B B Pattern side 2NA V615480 2 4 ...
Page 42: ...RS7000 42 D D PNSW Circuit Board 2NA V615500 2 1 ...
Page 43: ...RS7000 43 D D Pattern side 2NA V615500 2 1 ...
Page 45: ...RS7000 45 Pattern side 2NA V615490 2 1 ...
Page 56: ...RS7000 56 ...
Page 57: ...RS7000 57 ...
Page 58: ...RS7000 58 ...
Page 59: ...RS7000 59 ...
Page 60: ...RS7000 60 ...
Page 61: ...RS7000 61 ...
Page 62: ...RS7000 62 ...
Page 63: ...RS7000 63 ...
Page 64: ...RS7000 64 ...
Page 65: ...RS7000 65 ...
Page 69: ...RS7000 69 ...
Page 70: ...RS7000 70 ...
Page 71: ...RS7000 71 ...
Page 75: ...RS7000 75 ...