background image

RMio64-D Owner’s Manual

9

9

WORD CLOCK [Fs] indicator

Displays the word clock frequency that the unit is 
using. This indicator flashes if no word clock is 
synced.

)

Dante [SYSTEM] indicator

Displays the operating status of the unit.

!

Dante [SYNC] indicator

Displays the sync status between the Dante network 
and this unit.

@

[EXTERNAL CONTROL] indicator

This indicator turns on when a parameter which can 
be operated only from an external remote control is 
effective.

For details about parameters that can be operated 
by remote control, see “Remote Control” (page 16).

#

Power indicator
[I]/[

P

] (Power Switch)

Turns power of the unit to on [

I

] or off [

P

]. 

The indicator turns on when AC power is on.

 CAUTION

Even when the power switch is turned off, a small 

amount of current is flowing through the unit. When you 

are not using the product for a long time, make sure to 

unplug the power cord from the AC outlet.

NOTE

Rapidly turning the unit on and off in succession can cause 
it to malfunction. After turning the unit off, wait for at least 6 
seconds before turning it on again.

Rear Panel

$

AC IN connector

Connect the supplied AC power cord here. First 
connect the AC power cord to the RMio unit, then 
insert the power cord plug into an AC power outlet.
The supplied AC power cord features a V-lock 
mechanism via a latch, which prevents the power 
cord from coming off accidentally.
Insert the cable plug all the way until it locks in 
securely.

 CAUTION

Be sure to turn the power off before connecting or 

disconnecting the power cord.

Press the latch button on the plug to disconnect the 
power cord.

%

Dante [PRIMARY] connector
Dante [SECONDARY] connector

These are etherCON (RJ-45) connectors for 
connecting to the Dante network.

NOTE

• Use STP (Shielded Twisted Pair) cable to prevent 

electromagnetic interference. Make sure that the metal 
parts of the plugs are electrically connected to the STP 
cable shield by conductive tape or comparable means.

• Connect only Dante-compatible devices or GbE-

compatible devices (including a computer).

• Cables of up to 100 meters (theoretical value) can be 

used.

Green 
(indicator lights)

The unit is working properly.

Green 
(indicator flashes)

The firmware updating is in 
progress.

Red 
(indicator lights)

The memory on the unit does not 
work properly.

Red 
(indicator flashes)

The CPU on the unit does not work 
properly.

Green 
(indicator lights)

The device is working as the slave 
on the Dante network.

Green 
(indicator flashes)

The device is working as the 
master on the Dante network.

Orange 
(indicator lights)

Synchronization with the Dante 
network is in progress.

Orange 
(indicator flashes)

The device is not synchronized 
with the Dante network.

$

^

& *

B

C

(

%

A

D

E

Summary of Contents for RMio64-D

Page 1: ...ol Português Italiano Русский 日本語 Owner s Manual Bedienungsanleitung Mode d emploi Manual de instrucciones Manual do Proprietário Manuale di istruzioni Руководство пользователя 取扱説明書 JA RU IT PT ES FR DE EN I O RACK AUDIO INTERFACE ...

Page 2: ...en unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped UL60065_03 PRÉCAUTIONS CONCER NANT...

Page 3: ...he appropriate retailer please contact Yamaha Corporation of America Electronic Service Divi sion 6600 Orangethorpe Ave Buena Park CA90620 The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its subsidiaries This applies only to products distributed by YAMAHA CORPORATION OF AMERICA class B FCC INFORMATION U S A This applies only to products distributed...

Page 4: ... Input Rate 14 Panel Lock 14 Signal Flow 14 Dante to MADI 14 MADI to Dante 14 MADI Split 14 Word Clock 15 About Word Clock 15 Selecting a Word Clock Source 15 MADI SRC Sampling Rate Converter 15 Setting Examples 15 Displaying the MADI Input and Output Signals 16 Remote Control 16 Remote Controllable Parameters 16 Control from NUAGE Workgroup Manager 16 Direct Monitoring 17 RMio64 D Setup 17 Troubl...

Page 5: ...ct the electric plug from the outlet Then have the device inspected by Yamaha service personnel The power cord or plug becomes frayed or damaged It emits unusual smells or smoke Some object has been dropped into the device There is a sudden loss of sound during use of the device If this device should be dropped or damaged immediately turn off the power switch disconnect the electric plug from the ...

Page 6: ...personal use About this manual The illustrations and screens as shown in this manual are for instructional purposes only Windows is a registered trademark of Microsoft Corporation in the United States and other countries The company names and product names in this manual are the trademarks or registered trademarks of their respective companies weee_eu_en_01 rear_en_01 European Models Inrush Curren...

Page 7: ...g requirements to avoid heat buildup When mounting the unit in a rack with devices such as power amplifiers that generate a significant amount of heat leave more than 1U of space between the RMio and other equipment Also either leave the open spaces uncovered or install appropriate ventilating panels to minimize the possibility of heat buildup To ensure sufficient airflow leave the rear of the rac...

Page 8: ...ey Selects whether to display the MADI input signal or MADI output signal information frame format number of channels NOTE You can use this key to lock the panel to prevent operation of the keys page 14 6 MADI STATUS FRAME 48k indicator MADI STATUS FRAME 96k indicator Displays the frame format of the MADI input signal or output signal For 44 1 kHz and 48 kHz the STATUS FRAME 48k indicator is lit F...

Page 9: ...er outlet The supplied AC power cord features a V lock mechanism via a latch which prevents the power cord from coming off accidentally Insert the cable plug all the way until it locks in securely CAUTION Be sure to turn the power off before connecting or disconnecting the power cord Press the latch button on the plug to disconnect the power cord Dante PRIMARY connector Dante SECONDARY connector T...

Page 10: ...the default settings Dante channels 1 and 2 are used for output You can use a remote control to change the output channels For details see Remote Control page 16 A WORD CLOCK OUT connector WORD CLOCK IN connector These are BNC connectors used to transmit and receive word clock signals B MADI DIP switches Used to change unit settings Make sure to change the settings of the DIP switches while the po...

Page 11: ... functionality EEE functionality cannot be disabled for such switches EEE Energy Efficient Ethernet is a technology that reduces switch power consumption during periods of low network traffic It is also referred to as Green Ethernet and IEEE802 3az Connecting Dante compatible Devices You can connect the RMio64 D to a Dante network in the following ways Daisy Chain Network A daisy chain network is ...

Page 12: ... and a secondary circuit Normally the network operates on the primary circuit However if the primary connection is broken the secondary circuit will automatically take over communications Settings Turn on Dante DIP switch 1 DOWN If there are multiple Dante compatible devices from Yamaha that require an ID setting connected to the same network set a different ID for each device Make sure to change ...

Page 13: ...When removing the AC power cord perform these steps in reverse Press the latch button on the plug to disconnect the power cord WARNING The RMio64 D has been designed assuming it a proper ground connection is used To prevent electrical shock and damage to devices use the included AC power cord to create a secure ground connection If you do not know how to make a proper ground connection contact a Y...

Page 14: ...ock press and hold the MADI STATUS INPUT OUTPUT key for at least 3 seconds All front panel indicators except the power indicator flash indicating all controllers are locked To disengage the lock press and hold the MADI STATUS INPUT OUTPUT key for at least 3 seconds NOTE Even if the front panel is locked you can use remote control to make changes to the settings For the latest information about rem...

Page 15: ...lows you to connect a MADI compatible device having a different clock than the RMio64 D unit You can connect a Dante network and a MADI compatible device that are operating under different clocks without making any changes to either clock You can output MADI signals with a different word clock than the MADI input signal Setting Examples NOTE Output Clock Source in the following block diagram can b...

Page 16: ...es refer to the Yamaha Pro Audio website http www yamahaproaudio com Remote Controllable Parameters Control from NUAGE Workgroup Manager When RMio64 D is operating in the NUAGE Workgroup you can use remote control to configure the RMio64 D and use direct monitoring functions Word Clock Source Input Clock Source Output Clock Source DANTE MADI WCLK IN DANTE MADI Clock WCLK IN FOR SRC MADI IN Same as...

Page 17: ...and need help A mixer does not recognize the RMio64 D Is the Dante Unit ID set different ID from other Dante compatible devices from Yamaha that connected to the same network Is the network switch working properly The problem may be solved by turning the network switch on again Is the cable defective The problem may be solved by replacing the cable Audio cuts out or distorts Is the correct MADI in...

Page 18: ...vailable on the website http www yamahaproaudio com Remote Control I want to change the RMio64 D settings from the mixer I want to know the devices that can remotely configure the RMio64 D For details on RMio64 D remote control refer to the following website http www yamahaproaudio com Other Issues What is the latency of the Dante network The latency value can be set by Dante Controller or some mi...

Page 19: ...Star Network 12 UNIT ID 10 11 12 Direct monitoring 17 F Factory Settings 18 Firmware 7 17 18 I Included Accessories 4 Input rate 8 14 L Latency 18 Loop back 14 M MADI Coaxial connection 12 DIP switch 10 13 14 Input rate 8 14 16 Loop back 14 Optical connection 13 Redundant connection 13 MADI Split 14 MADI SRC Sampling Rate Converter 15 N Network switch 11 12 P Panel lock 14 Patching Audio routing 1...

Page 20: ...50ppm External 44 1kHz 48kHz 88 2kHz 96kHz 176 4kHz 192kHz 4 1667 0 1 0 1 4 0 200ppm 4 1667 0 1 0 1 4 0 200ppm 4 1667 0 1 0 1 4 0 200ppm 4 1667 0 1 0 1 4 0 200ppm 4 1667 0 1 0 1 4 0 200ppm 4 1667 0 1 0 1 4 0 200ppm MADI Channels Formats fs 44 1kHz 48kHz MADI Single fs 44 1 48k frame 56 64 channels fs 88 2kHz 96kHz MADI Double fs 44 1 48k frame 28 32 channels MADI Double fs 88 2 96k frame 28 32 cha...

Page 21: ...Format Data length Level Connector MADI IN 1 64 AES10 2008 MADI 24 bit ECL BNC Connector 31 14dBm SC Connector MADI OUT 1 64 ECL BNC Connector 20 14dBm SC Connector Terminal Level Connector WORD CLOCK IN TTL 75Ω terminated BNC Connector IN for SRC TTL 75Ω terminated BNC Connector OUT TTL 75Ω BNC Connector System Link Out 1 0 0 2Vp p 75Ω BNC Connector 480 44 13 349 12 374 361 Unit mm ...

Page 22: ... as above Same as above Same as above 64 64 1 2 3 4 64 MADI OUTPUT 1 64 up to 64ch 44 1 48kHz up to 32ch 88 2 96kHz up to 16ch 176 4 192kHz 64 64 SRC SRC 64 64 64 64 64 MADI COAXIAL INPUT 1 64 MADI OPTICAL INPUT 1 64 MADI COAXIAL OUTPUT 1 64 MADI OPTICAL OUTPUT 1 64 ENCODE SELECTOR DECODE 64 64 Effective when Direct Monitoring is ON Block Diagrams ...

Page 23: ...tation in the term modification Each licensee is addressed as you Activities other than copying distribution and modification are not covered by this License they are outside its scope The act of running the Program is not restricted and the output from the Program is covered only if its contents constitute a work based on the Program independent of having been made by running the Program Whether ...

Page 24: ...stribute the Program at all For example if a patent license would not permit royalty free redistribution of the Program by all those who receive copies directly or indirectly through you then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program If any portion of this section is held invalid or unenforceable under any particular circu...

Page 25: ... your program is a subroutine library you may consider it more useful to permit linking proprietary applications with the library If this is what you want to do use the GNU Library General Public License instead of this License Note on source code distribution For three years after the final factory shipment you may request from Yamaha the source code for any portions of the product which are lice...

Page 26: ...onte O código fonte pode ser baixado no seguinte endereço http www yamahaproaudio com Note sulla distribuzione del codice sorgente Entro tre anni dalla consegna di fabbrica finale è possibile richiedere a Yamaha il codice sorgente di qualsiasi parte del prodotto fornita con licenza GNU General Public License scrivendo al seguente indirizzo Pro Audio Department Audio Products Sales Marketing Divisi...

Page 27: ...s its criteria of freedom The Lesser General Public License permits more lax criteria for linking other code with the library We call this license the Lesser General Public License because it does Less to protect the user s freedom than the ordinary General Public License It also provides other free software developers Less of an advantage over competing non free programs These disadvantages are t...

Page 28: ...linked with it is called a work that uses the Library Such a work in isolation is not a derivative work of the Library and therefore falls outside the scope of this License However linking a work that uses the Library with the Library creates an executable that is a derivative of the Library because it contains portions of the Library rather than a work that uses the library The executable is ther...

Page 29: ... of software distributed through that system in reliance on consistent application of that system it is up to the author donor to decide if he or she is willing to distribute software through any other system and a licensee cannot impose that choice This section is intended to make thoroughly clear what is believed to be a consequence of the rest of this License 12 If the distribution and or use o...

Page 30: ...en wurde keiner Garantie unterliegt und dass Yamaha keine Verantwortung für den Quellcode übernimmt Der Quellcode kann von der folgenden Adresse heruntergeladen werden http www yamahaproaudio com Note concernant la distribution du code source Au cours des trois années qui suivent la sortie définitive d usine vous pouvez demander à Yamaha le code source de toute partie du produit fournie sous licen...

Page 31: ... Универсальная общественная лицензия ограниченного применения GNU обратившись по следующему адресу Pro Audio Department Audio Products Sales Marketing Division Yamaha Corporation 10 1 Nakazawa cho Naka ku Hamamatsu 430 8650 JAPAN Исходный код поставляется бесплатно однако вас могут попросить возместить корпорации Yamaha расходы по его пересылке Следует отметить что корпорация не несет ответственно...

Page 32: ......

Page 33: ...20 Lainate Milano Italy Tel 02 935 771 SPAIN PORTUGAL Yamaha Music Europe GmbH Ibérica Sucursal en España Ctra de la Coruna km 17 200 28231 Las Rozas Madrid Spain Tel 34 91 639 88 88 GREECE Philippos Nakas S A The Music House 147 Skiathou Street 112 55 Athens Greece Tel 01 228 2160 SWEDEN FINLAND ICELAND Yamaha Music Europe GmbH Germany filial Scandinavia JA Wettergrensgata 1 Västra Frölunda Swede...

Page 34: ...ed 11 2014 MWHD B0 2014 Yamaha Corporation Manual Development Department Printed in China ZJ70960 Yamaha Manual Library http www yamaha co jp manual Yamaha Pro Audio global web site http www yamahaproaudio com ...