General Specifications

Sampling frequency

Power requirements

Power cord length and temperature range

Control I/O standards

* The contents of this manual apply to the latest specifications as of the printing date. Since Yamaha makes continuous 

improvements to the product, this manual may not apply to the specifications of your particular product. To obtain the 
latest manual, access the Yamaha website then download the manual file. Since specifications, equipment or separately 
sold accessories may not be the same in every locale, please check with your Yamaha dealer.

Specifications

Conditions

Min.

Typ

Max.

Unit

External Clock

Frequency Range  Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz

–1000 

+1000

ppm

Jitter of PLL

*1

*1.

Input clock jitter must be 1ns or less.

WORD CLOCK IN Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 
96 kHz

10

ns

Internal clock

Frequency

Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz

44.1

48

88.2

96

kHz

Accuracy

Word clock : int 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz

–50

+50

ppm

Jitter

*2

*2.

Measured at the WORD CLOCK OUT connector.

Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz

4.5
4.1
2.3
2.1

ns

Conditions

Min.

Typ

Max.

Unit

Power consumption

100–240V    50/60 Hz

300

W

Heating value

100–240V    50/60 Hz

258

kcal/h

Conditions

Min.

Typ

Max.

Unit

Power cord length

250

cm

Temperature range

Operating temperature range

0

40

°C

Storage temperature range

–20

60

°C

Terminals

Format

Level

Connectors

WORD CLOCK

IN

TTL/75Ω terminated

BNC

OUT

TTL/75Ω

BNC

NETWORK

IEEE802.3

10BASE-T/100BASE-TX

etherCON CAT5

*1

*1.

STP cables (CAT5 or higher) are recommended for connection.

FAULT OUTPUT

NO

< DC30V, < 1A

Euro Block Connector 3P

C

*2

*2.

The C terminal normally short-circuits with the NC terminal, but it short-circuits with the NO terminal in the event that a fault is detected.

NC

< DC30V, < 1A

Summary of Contents for RIVAGE PM10

Page 1: ...I O RACK AUDIO INTERFACE RPio622 Owner s Manual EN...

Page 2: ...orms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plu...

Page 3: ...tisfactory results please contact the local retailer authorized to distribute this type of product If you can not locate the appropriate retailer please con tact Yamaha Corporation of America Electron...

Page 4: ...the power cord from the AC outlet Then have the device inspected by qualified Yamaha service personnel Never insert or remove an electric plug with wet hands Hearing loss Do not use speakers for a lo...

Page 5: ...f malfunction damage to the product damage to data or damage to other property follow the notices below Handling and maintenance Do not use the device in the vicinity of a TV radio stereo equipment mo...

Page 6: ...ards 13 Installing an RY Card 13 Removing the RY Card 14 Installing a Mini YGDAI Card 14 Removing the Mini YGDAI Card 14 Installing an HY Card 15 Removing the HY Card 15 Power Supply 16 Connecting the...

Page 7: ...n on updating the firmware please refer to the firmware update guide available on the website Precautions for Rack Mounting This unit is rated for operation at ambient temperatures ranging from 0 to 4...

Page 8: ...or has occurred Yellow lit steadily Indicates a minor issue but you can continue using the unit Green Normal Unit ID Specifies the Unit ID for the unit You must set a unique ID for each device connect...

Page 9: ...ni YGDAI I O cards 8 RY card slots 1 6 Enables you to install optional RY cards to configure I O ports The unit supports the following RY cards as of August 2015 RY16 ML SILK RY16 DA RY16 AE For the l...

Page 10: ...power cords from disconnecting accidentally NOTE Be sure to connect the power cords to power supply units A and B In this way if one of the power supply units malfunctions the other unit will supply p...

Page 11: ...air cable to prevent electromagnetic interference Make sure that the metal parts of the plugs are electrically connected to the STP cable s shield by conductive tape or comparable means The use of Eth...

Page 12: ...panel on the unit Preparation Cable preparation Use strand wires for the Euroblock plug First strip the strand wire insulation as shown below After the strand wires are connected to the Euroblock plug...

Page 13: ...the slot so that the connector at the end of the card is correctly inserted into the connector inside the slot 4 Fasten the card using the screws attached to the card If the card is not fastened secur...

Page 14: ...ead to component failure or electric shock 2 Remove the bottom screw and then the upper screw that fasten the slot cover to remove the slot cover Keep the cover and fixing screws in a safe place for f...

Page 15: ...each slot refer to Part Names and Functions on page 11 4 Pull up the card installation lever to lock in the card Make sure that the lever claw is securely locked under the bottom part of the slot NOTE...

Page 16: ...ght up yellow Please visit the Yamaha Pro Audio website for an FAQ list Frequently Asked Questions http www yamahaproaudio com No audio input is present Make sure that the cables are connected properl...

Page 17: ...FAN ERROR Red flashing The cooling fans are faulty LCD Messages Color Indicator Status Description Possible solution M1 ERR T0 TWINLANe WRONG LOOP Red flashing Fiber optic cable is not connected prop...

Page 18: ...nternal clock Frequency Word clock int 44 1 kHz Word clock int 48 kHz Word clock int 88 2 kHz Word clock int 96 kHz 44 1 48 88 2 96 kHz Accuracy Word clock int 44 1 kHz 48 kHz 88 2 kHz 96 kHz 50 50 pp...

Page 19: ...electronic products should not be mixed with general household waste For proper treatment recovery and recycling of old products please take them to applica ble collection points in accordance with y...

Page 20: ...RPio622 Owner s Manual 20 Dimensions Unit mm Approximate Munsell value of exterior color N5 350 65 480 440 15 455 13 350 50 490 450...

Page 21: ...CLAIM DAMAGES OR OTHER LIABILITY WHETHER IN AN ACTION OF CONTRACT TORT OR OTHERWISE ARISING FROM OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE uIP Copyright c...

Page 22: ...ware Updates 7 H HY card Installing 15 Removing 15 I Initialization 16 Initialz Initialize 9 Installing a Euroblock plug 12 L Lock mechanism of power cord 10 M MY card Installing 14 Removing 14 O Opti...

Page 23: ......

Page 24: ...PAIN PORTUGAL Yamaha Music Europe GmbH Ib rica Sucursal en Espa a Ctra de la Coruna km 17 200 28231 Las Rozas de Madrid Spain Tel 34 91 639 88 88 GREECE Philippos Nakas S A The Music House 19th klm Le...

Page 25: ...lished 08 2015 IPTO A0 2015 Yamaha Corporation Manual Development Department Printed in Japan ZP29290 Yamaha Downloads http download yamaha com Yamaha Pro Audio global website http www yamahaproaudio...

Reviews: