Yamaha RIVAGE PM Installation Manual Download Page 6

RIVAGE PM Editor Installation Guide

6

1

Use an Ethernet cable to connect the computer with PM Editor to the RIVAGE PM system.

Connect the computer where PM Editor is installed to the DSP engine. To establish a connection with the DSP 
engine, connect the cable to the NETWORK terminal (PC) located next to the TO CONSOLE terminal. Never 
connect the cable to the NETWORK terminal above the HY card slots.
Alternatively, you can connect the cable to the NETWORK terminal on the control surface. Note that in the 
RIVAGE PM10 system, connection with the DSP engine will be cut off and the communication cannot be 
established if you turn off the power to the control surface.

NOTE

• For RIVAGE PM Editor earlier than V2.0.0, only one PM Editor can be used per system. RIVAGE PM Editor V2.0.0 or later allows 

use of up to two per system. Do not connect computers exceeding the usable number. 

• When you are using two PM Editors for one system, connect the computers to each NETWORK connector of the DSP engine 

and the console surface or connect the computers via the switching hub.

2

Activate PM Editor. 

In Windows 7: “Start” 

 “All Programs” 

 “RIVAGE PM Editor”

In Windows 8.1/Windows 10: Click the “RIVAGE PM Editor” tile on the “Start” screen
In Mac: Open the “Applications,” and then double-click “RIVAGE PM Editor”

NOTE

If the “User Account Control” dialog box appears, click [Yes].

After you activate the software, a popup window for establishing a 
connection appears. 
Select “MIXER TYPE,” and then click the [Connect] button to start 
PM Editor.

Connection and Activation

Computer with 

PM Editor

DSP Engine DSP-R10

Control Surface

or

Console 
Network

Summary of Contents for RIVAGE PM

Page 1: ...ode form of the SOFTWARE by any method whatsoever You may not reproduce modify change rent lease or distribute the SOFTWARE in whole or in part or create derivative works of the SOFTWARE You may not electronically transmit the SOFTWARE from one computer to another or share the SOFTWARE in a network with other computers You may not use the SOFTWARE to distribute illegal data or data that violates p...

Page 2: ...rpreted according to and governed by Japanese law without reference to principles of conflict of laws Any dispute or procedure shall be heard before the Tokyo District Court in Japan If for any reason a court of competent jurisdiction finds any portion of this Agreement to be unenforceable the remainder of this Agreement shall continue in full force and effect 8 COMPLETE AGREEMENT This Agreement c...

Page 3: ...o not connect computers exceeding the usable number When you are using two PM Editors for one system connect the computers to each NETWORK connector of the DSP engine and the console surface or connect the computers via the switching hub If you synchronize PM Editor with DSP R10 CSD R7 any RECALL UNDO that was enabled until that point is reset Step 1 Installation and Network Configuration 1 Check ...

Page 4: ...ded to run the PM Editor 1 Extract the downloaded file and double click setup exe Windows or Yamaha RIVAGE PM Editor Vx x x pkg Mac The setup dialog of the PM Editor is displayed NOTE x x x represents the firmware version number Click Continue or Yes if the User Account Control window appears 2 Follow the on screen instructions and install the software Installing the PM Editor and making the netwo...

Page 5: ...dialog box appears instead skip ahead to step 4 3 Click Properties The Local Area Connection properties dialog box is called up 4 Select Internet Protocol Version 4 TCP IPv4 then click Properties The Internet Protocol Version 4 TCP IPv4 Protocol dialog box is called up 5 Click Use the following IP address 6 Enter your computer s IP address into IP address and the Subnet mask into Subnet mask 7 Cli...

Page 6: ...an V2 0 0 only one PM Editor can be used per system RIVAGE PM Editor V2 0 0 or later allows use of up to two per system Do not connect computers exceeding the usable number When you are using two PM Editors for one system connect the computers to each NETWORK connector of the DSP engine and the console surface or connect the computers via the switching hub 2 Activate PM Editor In Windows 7 Start A...

Page 7: ... Ethernet cable to connect the computer directly to the RIVAGE PM system Confirm that the cable is connected to the correct terminal Connect either to the control surface or to DSP R10 Do not connect to both of them Page 6 Is there any resident security software installed If the firewall function of anti virus or security software is enabled the communication may not be established properly Are th...

Reviews: