Chapter 5 EXTERNAL SAFETY CIRCUIT EXAMPLES
5.1.2 Circuit examples for the RCX240
The following shows category-specific safety circuit configuration examples for the
RCX240.
Customers should install the appropriate safety measures for their system by referring to
these safety circuit configuration examples in order to use the robots more safely.
The example shown here provide the following input/output signals.
Input
Reset switch, maintenance mode switch, door switch, and external emergency stop
Output
Programming box emergency stop output and enable output
c
CAUTION
The controller status output signals of the parallel I/O and serial I/O, such as
alarm signals, should be monitored by the host device.
■
Overall connection diagram (with enable switch)
AC OUT
Emergency stop Enable
17
18
19
20
13
14
15
16
3
Controller
(PNP specifications)
I24V
Safety circuit
External
emergency stop
Door
Maintenance
AC IN
RPB-E
OUT
Safety output
RPB
SAFETY
MPRDY
Status
Reset
N1
L1
N
L
N1
L1
4
5
6
7
8
9
10
1
2
11
13
14
SERVICE(DI02)
MPRDY
E-STOP24V
E-STOPRDY
+5V
P.COM
P.COMDI
N.COMDI
12 N.COM
E-STOP
Status
GND
+24V_GND
47
48
49
50
27
29
STD.DIO
COMMON
CPU_OK (contact A (normally open))
P.COMDI
N.COMDI
+24V
GND
KA1
+24V
GND
To PLC
Input/output signals
KA1
+24V
GND
Wiring to check whether controller
is normal when using alarm to shut
off main power
Wiring to check whether controller is
normal when not using alarm to shut
off main power
5.1 External safety circuit examples
Summary of Contents for RCX240
Page 2: ......
Page 4: ...MEMO 2 Introduction...
Page 8: ...MEMO iv General contents...
Page 10: ......
Page 22: ......
Page 26: ...MEMO 2 4 Chapter 2 CE MARKING...
Page 28: ......
Page 44: ......
Page 56: ...4 12 Chapter 4 EMC COUNTERMEASURE MEMO...
Page 58: ......
Page 72: ...MEMO 5 14 Chapter 5 EXTERNAL SAFETY CIRCUIT EXAMPLES...
Page 74: ......
Page 91: ...MEMO...