4.9 Installing a surge absorber
Users who wish to improve immunity to surge noise from lightning strikes should install a
surge absorber.
■
Dimensional outlines of recommended surge absorber
Manufacturer : SOSHIN ELECTRIC CO., LTD.
Type No.
: LT-C12G801WS
Status indicator
φ
4.3
+0.3
-0.1
25
±
1.0
4
33.5
±
1.0
19
±
1.0
Wire
(
line
)
(
Black
)
Wire
(
earth
)
(
Green/Yellow
)
38
±
1.0
22.5
±
1.0
250
+25
-0
28
±
1.0
4
±
0.5
Green : Normal
Red : Abnormal
4. Connecting to the power