1. SAFETY I/O interface overview
The robot controller is provided with SAFETY I/O interfaces for compatibility with the
system used by the customer. A description of the I/O terminals and connection methods
are explained below. Connect the I/O terminals correctly for effective operation.
The input signal is referred to as DI and the output signal as DO.
Specifications
SAFETY
Connector type No.
KAS-M5370-001
Sumitomo 3M
Connector shell
10320-52A0-008
Connector plug
10120-3000PE
Wire material 0.2 sq
1.1 Power
The emergency stop ready signal utilizes internal power for input signal.
Dedicated I/O requires an external 24V DC power supply. Connect the 24V DC power
supply to DI.COM and DO.COM.
c
CAUTION
Do not keep supplying the external 24v DC power to the SAFETY connector
while controller power is off. The controller might malfunction if the external
24v is continuously supplied.