5-20
Chapter
5
PARALLEL I/O INTERF
ACE
5-21
1.9.4 Mode switching
■
Mode switching
DI13
AUTO mode
switching
DI16
MANUAL mode
switching
DO10 AUTO mode
• "AUTO" and "MANUAL" modes can be switched independent of DI00 (Emergency
stop ready signal) and DI11 (Interlock input) status.
• After switching to "AUTO" mode, make sure that DO10 ("AUTO" mode output) is
on and then turn off DI13 ("AUTO" mode switching).
• No dedicated output is available that indicates the operation has switched to
"MANUAL" mode. The "on" period of DI16 ("MANUAL" mode switching) input
pulse must be longer than 10msec.
n
NOTE
The DI00 (Emergency stop ready signal) and DI11 (Interlock input) input
terminals are located in the SAFETY connector. See Chapter 6 for detailed
information.
1. Standard I/O interface overview
Summary of Contents for RCX222
Page 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 14: ......
Page 43: ......
Page 46: ......
Page 50: ...4 MEMO ...
Page 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Page 52: ......
Page 56: ......
Page 98: ......
Page 388: ......
Page 412: ...5 24 MEMO ...
Page 414: ......
Page 430: ......
Page 442: ......
Page 450: ...8 8 MEMO ...
Page 452: ......
Page 523: ......