6.1 Parameter setting for CC-Link serial I/O board
[Operation]
1. Press the
F 1
(PARAM) key in "SYSTEM" mode to enter "SYSTEM>PARAM" mode.
2. Press the
F 5
(OP. BRD) key in "SYSTEM>PARAM" mode to enter the option board
parameter setting mode.
The option boards installed in the controller are displayed in order on the MPB
screen.
SYSTEM
>PARAM>OP.BRD V8.18
1.DIO_N(1) VALID
2.. −−−
3.CCLnk(S1/10M) VALID
4. −−−
SELECT
Option boards installed into the option slots are displayed on the MPB screen.
Type
Display
Meaning
Option DIO
DIO_N(n)
An option DIO board of NPN specifications is installed. The
number in parentheses is an ID number.
DIO_P(n)
An option DIO board of PNP specifications is installed. The
number in parentheses is an ID number.
Serial I/O
CCLnk(n/m)
A CC-Link unit is installed. Letters in parentheses indicate a
station number "n" and a communication speed "m".
D_Net(n/m)
A DeviceNet unit is installed. Letters in parentheses indicate a
MAC ID number "n" and communication speed "m".
Profi(n/m)
A Profibus unit is installed. Letters in parentheses indicate a
station address "n" and communication speed "m".
Network
E_Net
An Ethernet unit is installed.
YC-Link
YCLnk(Mn)
A YC-Link unit is installed. Letters in parentheses indicate a
station number "n".
3. In "SYSTEM>PARAM>OP. BRD" mode, select the "CCLnk" with the cursor (
↑
/
↓
) keys
and press the
F 1
(SELECT) key.
SYSTEM
>PARAM>OP.BRD>SELECT V8.18
1.board condition VALID
2.remote cmd / IO cmd(SI05) VALID
3.Output MSG to SOW(1) INVALID
EDIT JUMP
6. Parameter setting for CC-Link serial I/O board
Summary of Contents for RCX series
Page 1: ...User s Manual ENGLISH E E78 Ver 1 08 CC Link YAMAHA NETWORK BOARD RCX series ...
Page 2: ......
Page 12: ......
Page 22: ......
Page 34: ...2 12 MEMO ...
Page 36: ......
Page 50: ......
Page 60: ......
Page 81: ...Chapter 6 APPENDIX Contents 1 Term definition 6 1 ...
Page 82: ......