(3-4) NON-REGISTERED PARAMETER NUMBER
STATUS
1011nnnn (BnH)
n = 0 ~ 15 VOICE CHANNEL NUMBER
LSB
01100010 (62H)
RPN LSB
0ppppppp
p = NRPN LSB (Refer to the table on the following page.)
MSB
01100011 (63H)
RPN MSB
0qqqqqqq
q = NRPN MSB (Refer to the table on the following page.)
DATA ENTRY MSB
00000110 (06H)
DATA VALUE
0mmmmmmm
m = Data Value
First transmit an NRPN MSB and NRPN LSB to specify the parameter that is to be controlled, then use
Data Entry to set the value of the specified parameter.
NRPN
D.ENTRY
MSB LSB
MSB
LSB
PARAMETER NAME
DATA RANGE
01H 08H
mmH —
VIBRATO RATE
00H - 40H - 7FH (-64 - 0 - +63)
01H 09H
mmH —
VIBRATO DEPTH
00H - 40H - 7FH (-64 - 0 - +63)
01H 0AH
mmH —
VIBRATO DELAY
00H - 40H - 7FH (-64 - 0 - +63)
01H 20H
mmH —
FILTER CUTOFF FREQUENCY
00H - 40H - 7FH (-64 - 0 - +63)
01H 21H
mmH —
FILTER RESONANCE
00H - 40H - 7FH (-64 - 0 - +63)
01H 63H
mmH —
EG ATTACK TIME
00H - 40H - 7FH (-64 - 0 - +63)
01H 64H
mmH —
EG DECAY TIME
00H - 40H - 7FH (-64 - 0 - +63)
01H 66H
mmH —
EG RELEASE TIME
00H - 40H - 7FH (-64 - 0 - +63)
14H rrH
mmH —
DRUM INST FILTER CUTOFF FREQ.
00H - 40H - 7FH (-64 - 0 - +63)
15H rrH
mmH —
DRUM INST FILTER RESONANCE
00H - 40H - 7FH (-64 - 0 - +63)
16H rrH
mmH —
DRUM INST AEG ATTACK RATE
00H - 40H - 7FH (-64 - 0 - +63)
17H rrH
mmH —
DRUM INST AEG DECAY RATE
00H - 40H - 7FH (-64 - 0 - +63)
18H rrH
mmH —
DRUM INST PITCH COARSE
00H - 40H - 7FH (-64 - 0 - +63)
19H rrH
mmH —
DRUM INST PITCH FINE
00H - 40H - 7FH (-64 - 0 - +63)
1AH rrH
mmH —
DRUM INST LEVEL
00H - 7FH (0 - maximum)
1CH rrH
mmH —
DRUM INST PANPOT
00H, 01H - 40H - 7FH
(random, left - center - right)
1DH rrH
mmH —
DRUM INST REVERB SEND LEVEL
00H - 7FH (0 - maximum)
1EH rrH
mmH —
DRUM INST CHORUS SEND LEVEL
00H - 7FH (0 - maximum)
1FH rrH
mmH —
DRUM INST VARIATION SEND LEVEL
00H - 7FH (0 - maximum)
MSB 14h-1Fh (for drum) are valid only if the channel is set to Drum Set Mode.
rrH : drum instrument note number
(3-5) SYSTEM REAL TIME MESSAGES
(3-5-1) ACTIVE SENSING
STATUS
11111110
(FEH)
Transmitted at intervals of approximately 200 msec.
Once this message is received, SENSING will begin. If neither STATUS nor DATA messages are received
for an interval longer that approximately 350 msec, the MIDI RECEIVE BUFFER will be cleared, and all
sounding notes and SUSTAIN SWITCH will be forced off. Also, data for each of the controls will be reset
to specific values.
(3-6) SYSTEM EXCLUSIVE MESSAGE
(3-6-1) UNIVERSAL NON REALTIME MESSAGE
(3-6-1-1) GENERAL MIDI MODE ON
F0H 7EH 7FH 09H 01H F7H
The following controller values will be reset.
VOLUME
100
PAN
Center
PROGRAM CHANGE
1 (Grandpno)
BANK SELECT MSB
0
M I D I D a t a F o r m a t
46
46