Yamaha NUAGE I/O Nio500-A8D8 Supplementary Manual Download Page 7

NUAGE V1.6 Supplementary Manual

7

Added Support for RMio64-D 
(NUAGE Workgroup Manager)

You can now control the RMio64-D Dante/MADI 
conversion audio interface remotely from NUAGE 
Workgroup Manager.

NOTE

• For remote control operation, the target RMio64-D must be 

active in NUAGE Workgroup.

• Modifications to parameters are applied to the RMio64-D unit 

as soon as they are changed.

• A total of eight Nuage I/O and RMio64-D units can be 

registered in a Workgroup.

RMio64-D – Property Window

The parameters that can be controlled are as follows:

1

Version

Displays the firmware version of the RMio64-D unit. You 
can update the firmware by clicking “Update.”

2

Word Clock Source

Enables you to select the word clock source for the 
RMio64-D (from Dante/WCLK IN/MADI).

3

SRC

Enables you to turn MADI SRC (Sampling Rate Converter) 
on/off.

4

Input Clock Source

Enables you to select the word clock source for SRC input 
(from MADI/WCLK IN for SRC).

5

Output Clock Source

Enables you to select the MADI output signal when SRC is 
on as the word clock source. 

6

Input Rate

Enables you to select from 1Fs (1x)/2Fs (2x)/4Fs (4x) 
according to the MADI input frequency. For example, if the 
MADI input signal is 192 kHz (4x 48 kHz), select “4Fs.”

7

MADI Output Frame

Enables you to select the frame frequency for the MADI 
output signal. It is possible for the selected value to differ 
from the actual frequency. For example, when the setting 
is “96kHz” and the actual frequency is “48kHz,” for 
example, “96kHz >> 48kHz” is displayed. 

8

MADI Output Channel

Enables you to select the number of channels for the 
MADI output signal. It is possible for the selected value to 
differ from the actual number of channels. When the 
setting is “64” and the actual number of channels is “56,” 
for example, “64 >> 56” is displayed. 

9

Panel Lock

Unlocks/locks panel operation for the RMio64-D unit.

MADI Output Signal when SRC is On

2

1

9

3

6

4

5

7

8

Same as Input 
Clock Source

Syncs the MADI output signal with the 
MADI input signal.

Same as Word 
Clock Source

Syncs the MADI output signal with the 
RMio64-D clock.

Same as Input

Outputs the same frame frequency as the 
MADI input signal.

48kHz

Outputs at 44.1 kHz or 48 kHz.

96kHz

Outputs at 88.2 kHz or 96 kHz.

Same as Input

Outputs the same number of channels as 
the MADI input signal.

64

Outputs on 64 channels.

56

Outputs on 56 channels.

Input Clock 
Source

Output Clock 
Source

MADI Output 
Signal

MADI

Same as Input 
Clock Source

Synced with MADI 
Input Signal

MADI

Same as Word 
Clock Source

Synced with 
RMio64-D clock

WCLK IN for SRC

Same as Input 
Clock Source

Synced with word 
clock input from 
WCLK IN for SRC

WCLK IN for SRC

Same as Word 
Clock Source

Synced with 
RMio64-D clock

Summary of Contents for NUAGE I/O Nio500-A8D8

Page 1: ...page 5 Added support for switching parameters in Channel Setting mode Nuage Fader page 5 Added key function shortcut for dividing events into selected ranges Nuage Master page 5 Added collective bypass function for inserts Nuage Fader page 6 Added collective bypass function for dynamics Nuage Master page 6 Added support for switching between multiple Avid Pro Tools NUAGE Workgroup Manager page 6 A...

Page 2: ...yond the second level are all displayed in the second level Workspace Extension The first four workspaces displayed in Workspace Organizer can be loaded from the WORKSPACE section in Nuage Fader For example if there are three Global Workspaces and two Project Workspaces the three Global Workspaces and then one Project Workspace are assigned successively to WORKSPACE 1 to WORKSPACE 4 High Cut and L...

Page 3: ...Fader You can also use Multi function button B to switch between Pre Fader and Post Fader Recording MIDI Events to the Tracks You can adjust the following parameters on the INSERT page of Nuage Master CHANNEL CONTROL 1 MIDI Audio Only for Instrument Tracks Switches the type of plug in To record the MIDI events select MIDI 2 Record Output to Track Selects lit and deselects dim a MIDI track or instr...

Page 4: ...bus as Nuage I O will be displayed in gray italics regardless of whether direct monitoring is enabled or disabled For more information about direct monitoring with the RMio64 D refer to the RMio64 D Owner s Manual If input from Nuage I O and input from RMio64 D are mixed and then output for direct monitoring to the same Nuage I O port only the input from Nuage I O is output Added Stereo Panner Swi...

Page 5: ...s of Dynamics are currently supported DeEsser Cubase Pro 8 and later Envelope Shaper Operation With either DeEsser or Envelope Shaper selected in Dynamics in the channel displayed in Channel Setting mode do the following 1 Press DYN in the SECTION CONTROL section 2 Press Sub parameter 2 The parameter display in the label area is switched 3 Adjust the parameter using the corresponding Multi functio...

Page 6: ...ndow This function is disabled if two channels are displayed in Channel Setting mode Added Collective Bypass Function for Dynamics Nuage Master You can now turn bypass on off for Dynamics on the selected channels Operation 1 Select the track for turning dynamics on off 2 Press DYNAMICS in the MULTI FUNCTION DISPLAY section The CHANNEL CONTROL DYN page is displayed in the Multi function display 3 T...

Page 7: ...ables you to select the frame frequency for the MADI output signal It is possible for the selected value to differ from the actual frequency For example when the setting is 96kHz and the actual frequency is 48kHz for example 96kHz 48kHz is displayed 8 MADI Output Channel Enables you to select the number of channels for the MADI output signal It is possible for the selected value to differ from the...

Page 8: ... the window Since Cubase does not have an ADR function Marker ID Take Number are not displayed in the window Added a Function for Project Cursor Positioning Nuage Master You can now enter values in units of hours minutes and seconds to position the Project Cursor on the TRANSPORT page Settings Switch the input method in Numeric Pad Input on SETUP Page PAGE 3 SETUP Page PAGE 3 NOTE If you change th...

Page 9: ...l operation during Project playback Doing so will prevent unintended operation of the Project cursor during playback Settings Switch the setting by using the JOG Operation during Playback control on SETUP Page PAGE 3 SETUP Page PAGE 3 On Enables Jog wheel operation during Project playback Off Disables Jog wheel operation during Project playback ...

Page 10: ...Manual Development Department 2014 Yamaha Corporation 412MW A0 Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manual ...

Reviews: