188
Chapter 17—Remote Control
01V96—Owner’s Manual
Configuring the 01V96
Follow the steps below to set up the 01V96 so that you can remotely control Pro Tools from
the 01V96 Remote Layer.
1 Press the DISPLAY ACCESS [DIO/SETUP] button repeatedly until the
DIO/Setup | MIDI/Host page appears.
2 Move the cursor to the first DAW parameter box in the SPECIAL FUNCTIONS
section, then rotate the Parameter wheel to select USB as the port.
3 Press [ENTER] to confirm the setting.
4 Move the cursor to the adjacent
parameter box (on the right), then
rotate the Parameter wheel to spec-
ify the port ID.
5 Press the DISPLAY ACCESS [DIO/SETUP] button repeatedly until the
DIO/Setup | Remote page appears.
6 Select ProTools (as the target device) for the Target parameter (
1
) located
in the upper-right corner of the page.
By default, the Remote layer target is set to ProTools. If another target has been selected,
rotate the Parameter wheel to select ProTools.
Note:
If you select an incorrect port, you will be unable to use the Remote function. Be sure
to match the port ID with that specified in the Peripherals window in Pro Tools.
1
Summary of Contents for MIXING CONSOLE
Page 1: ...E Owner s Manual Keep This Manual For Future Reference ...
Page 46: ...46 Chapter 4 Connections and Setup 01V96 Owner s Manual ...
Page 96: ...96 Chapter 7 Input Channels 01V96 Owner s Manual ...
Page 108: ...108 Chapter 8 Bus Outs 01V96 Owner s Manual ...
Page 130: ...130 Chapter 10 Input Output Patching 01V96 Owner s Manual ...
Page 160: ...160 Chapter 14 Internal Effects 01V96 Owner s Manual ...
Page 170: ...170 Chapter 15 Scene Memories 01V96 Owner s Manual ...
Page 184: ...184 Chapter 16 Libraries 01V96 Owner s Manual ...
Page 224: ...224 Chapter 18 MIDI 01V96 Owner s Manual ...
Page 329: ...Index 329 01V96 Owner s Manual ...