11
RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS
Selection by using the remote control unit
The remote control codes in the menu list (See right column on page 8) correspond to the DSP program test and
effect keys.
3. OPERATION AND DISPLAY WHEN STARTING DIAGNOSIS FUNCTION
(1) Selection of diagnostic menu
The diagnostic menu and the sub-menu can be selected by using the front panel keys of the main unit or the remote
control unit.
Selection by using the front panel keys
The main menu can be changed cyclically by using the "TUNING UP/DOWN" keys, and the submenu, by using the
"PROGRAM / " keys. The "UP" or " " key will increase the main or submenu number.
(2) Other functions available while diagnosis function is active
Listed below are the other functions available while the diagnosis function is active.
• Selecting input source (Tape monitor/Ext. decoder)
• Adjusting effect level (Center, Rear, Sub-woofer)
• Adjusting master volume
• Muting on/off
• Power on/off
(3) Diagnosis default status
When not otherwise specified, default settings and values in each menu are as follows:
• All SPEAKERS : LARGE
• ALL electronic VRs : 0dB
• DYNAMIC RANGE : MAX
• LFE LEVEL : 0dB (–10dB DOLBY DIGITAL LFE)
• CENTER DELAY : 0ms
DOWN
UP
TUNING
TIME/
LEVEL
SET
MENU
INPUT MODE
EFFECT
PROGRAM
FRONT PANEL
Main menu
Sub menu
Reverse Forward
Reverse Forward