3-5
INSP
ADJ
E
CONTROL SYSTEM
QSTS cable inspection and adjustment
1. Measure:
●
Nozzle deflector set length
a
,
b
Difference
→
Adjust.
Measurement steps:
●
Set the control grip in the neutral posi-
tion.
●
Measure the nozzle deflector set
length
a
and
b
.
●
If
a
and
b
length are not even, adjust
the cable joint.
2. Adjust:
●
QSTS cable
Adjustment steps:
●
Set the control grip in the neutral posi-
tion.
●
Loosen the locknut
1
.
●
Remove the nut
2
and pivot pin
3
.
●
Set the jet nozzle in the center posi-
tion.
●
Turn the cable joint
4
for adjusting.
Turn in
Length
b
is increased.
Turn out
Length
a
is increased.
WARNING
The cable joint must be screwed in more
than 8 mm (0.31 in).
●
Connect the cable joint
4
and pivot
pin
3
and tighten the nut
2
.
T
R
.
Nut:
4 Nm (0.4 m • kgf, 2.9 ft • lb)
●
Tighten the locknut
1
.
T
R
.
Locknut:
4 Nm (0.4 m • kgf, 2.9 ft • lb)