ELEC
Electrical system
–
+
8-9
67C3K11
Removing the starter motor
1.
Remove the starter motor from the power
unit.
NOTE:
• Check the engine start switch, neutral
switch, starter relay, and fuse before
removing the starter motor.
• To remove the starter motor, see “Starter
motor, starter relay, and PTT relay (E and
W model)” (5-15).
Checking the starter motor operation
1.
Hold the starter motor in a vise using alu-
minum plates on both sides.
2.
Connect the positive battery cable
1
to
the starter relay terminal
2
, connect the
starter motor lead
3
to the starter motor
positive terminal
4
, and connect the
negative battery cable
5
to the starter
motor body
6
.
3.
Connect the starter relay lead (brown)
7
to the positive battery terminal. Connect
the starter relay lead (black)
8
to the
negative battery terminal to check the
starter motor operation.
WARNING
Do not place any objects near the pinion
or touch it. The pinion
9
moves slightly
away from the starter motor body and
rotates at high speed.
NOTE:
• Check the starter motor operation for a few
seconds.
• If the starter motor is disassembled for
maintenance, be sure to check the opera-
tion again after assembling it.
4.
Disconnect the negative battery cable
and positive battery cable from the bat-
tery terminals.
Disassembling the starter motor
1.
Remove the bracket
1
and stator
2
.
2.
Remove the nut
3
, washer
4
, pinion
stoppers
5
, and spring
6
, and then
remove the pinion
7
and cover
8
from
the armature
9
.
S67C8014
B
R
B
Br
R
6
1
7
4
5
9
4
2
3
8
6
5
8
7
1
2
3
S67C8017
2
1
Summary of Contents for F30A
Page 1: ...F30A F40B SERVICE MANUAL 67C 28197 3K 11 ...
Page 4: ......
Page 26: ...GEN INFO General information 1 21 67C3K11 MEMO ...
Page 150: ...POWR Power unit 5 55 67C3K11 MEMO ...
Page 236: ...BRKT Bracket unit 7 55 67C3K11 MEMO ...
Page 282: ......
Page 283: ...YAMAHA MOTOR CO LTD Printed in China Aug 2007 1 2 1 CR E ...