5-39
ELEC
Electrical system
3.
Turn the engine start switch to ON, and
then measure the input voltage between
the terminal
a
and ground, and the
terminal
b
and ground.
4.
Turn the engine start switch to ON, and
then measure the input voltage between
the terminals
b
and
c
.
5.
Turn the engine start switch to OFF.
6.
Install the high-pressure fuel pump relay
a
and relay cover.
Checking the vapor shut-off valve
1.
Disconnect the vapor shut-off valve cou-
pler
a
.
2.
Turn the engine start switch to ON, and
then measure the input voltage between
the vapor shut-off valve coupler terminal
and ground.
3.
Remove the vapor shut-off valve, and
then connect the special service tool
a
to the vapor shut-off valve.
4.
Apply the specified negative pressure to
the vapor shut-off valve.
5.
Check that the vapor shut-off valve
opens and the negative pressure is
released when the battery leads are
connected to the vapor shut-off valve
terminals.
NOTICE:
Do not connect
the battery leads to the vapor shut-off
valve terminals for more than a few
seconds.
High-pressure fuel pump relay input
voltage:
Terminal
a
–Ground
Terminal
b
–Ground
12.0 V (battery voltage)
High-pressure fuel pump relay input
voltage:
Terminal
b
–Terminal
c
12.0 V (battery voltage)
a
b
c
b
Vapor shut-off valve input voltage:
Red/Yellow (R/Y)–Ground
12.0 V (battery voltage)
Vacuum/pressure pump gauge set
a
:
90890-06756
Specified negative pressure:
67.0 kPa (0.67 kgf/cm
2
, 9.7 psi)
R/Y
a
a
Summary of Contents for F225F
Page 1: ...SERVICE MANUAL 6CE 28197 3N 11 F L 225F F L 250D F L 300B ...
Page 4: ......
Page 54: ...1 31 SPEC Specification MEMO ...
Page 89: ...2 34 Lower unit 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 263: ...6 28 Canister 0 1 2 3 4 5 6 7 8 9 10 A j k f b ...
Page 477: ...8 98 Shimming counter rotation model 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 537: ...9 58 PTT cylinder 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Page 562: ...A 1 MEMO ...
Page 565: ......
Page 566: ...May 2010 1 ABE E_1 YAMAHA MOTOR CO LTD ...
Page 576: ...A 13 ...