42
RX-V3300/DSP-AZ2
RX-V3300/DSP-AZ2
■
AMP CHECK
• Confirmation of Idling Current
1) No signal applied.
2) Non-loaded condition.
3) Aging is 10 minutes.
● アイドリング電流の確認
無信号・無負荷状態で、電源投入10分後に行ってくださ
い。
Item / チャンネル
Test Point / テストポイント
Rating (DC) / 規格(DC)
MAIN L
Q64 Base – Emitter (MAIN [1] P.C.B.)
MAIN R
Q62 Base – Emitter (MAIN [1] P.C.B.)
CENTER
Q10 Base – Emitter (MAIN [2] P.C.B.)
REAR CENTER
Q60 Base – Emitter (MAIN [1] P.C.B.)
100m – 300mV
REAR L
Q58 Base – Emitter (MAIN [1] P.C.B.)
REAR R
Q56 Base – Emitter (MAIN [1] P.C.B.)
FRONT L
Q6 Base – Emitter (MAIN [2] P.C.B.)
FRONT R
Q8 Base – Emitter (MAIN [2] P.C.B.)
• Test Point
● テストポイント
MAIN [1] P.C.B.
MAIN [2] P.C.B.
Q56
100 – 300 mV
REAR (R)
Q58
100 – 300 mV
REAR (L)
Q60
100 – 300 mV
REAR (C)
Q62
100 – 300 mV
MAIN (R)
Q64
100 – 300 mV
MAIN (L)
Q10
Q8
100 – 300 mV
CENTER
100 – 300 mV
FRONT (R)
Q6
100 – 300 mV
FRONT (L)