Chapter 6
Component Guide
DME Designer Owner’s Manual
454
MY-Card
This shows the input and output for the card inserted into the DME expansion slot. The following
components are available, depending on the card types:
Input Format/Output Format
This is the I/O mode for high sample rate operation (88.2/96 kHz).
In the Double Channel Mode, high sampling rate data (88.2/96 kHz) is transmitted and received by
two channels, each channel handling the digital audio data at half the sampling rate. For this reason
the total number of available channels is halved, and even-numbered channels are unavailable.
In the Double Speed Mode digital audio data is transmitted and received at the current high sampling
rate (88.2/96 kHz).
In the Single Mode digital audio data is transmitted and received at half the current high sampling rate
(88.2/96 kHz).
Setting Examples
When the MY card word clock is used as the master word clock, Double FS determines whether the
speed of that word clock is to be doubled and used as the DME clock. The Double Fs setting is only
available the word clock from an MY Card is used.
Operation clock of related equipment
The DME operation clock
Input Format/Output Format
88.2/96 kHz (Double Channel)
88.2/96 kHz
Double Channel
88.2/96 kHz (Double Speed)
Double Speed
44.1k/48k
Single