(3) Automatic Check Test
●
In case of one test pattern
After completion of a test under the automatic test
items, test data may be displayed in addition to the
OK/NG indication as a test result. If the [ENTER] key
is pressed on this screen, it will return to the Testing
Item Selection List Screen.
●
In case of multiple test pattern
Selection Setting Screen
When the [ENTER] key is pressed on the Test Pattern
Selection Setting Screen, it will change to a screen for
execution and result of the corresponding test. When
the [CANCEL] key is pressed, it will return to the Testing
Item Selection List Screen. In this case, NG will be
displayed to the corresponding test in the list to indicate
that it was interrupted.
Executed Result Display Screen
To show the executing state of each testing item, the state
is indicated as OK or NG on the right side of the
corresponding testing item on the Testing Item Selection
List Screen. No state identification is displayed for those
items which have not been tested once.
1-0-5 Exit from Determination and Execution Screen
of Each Test
Exiting the checking method and execution screen of
each test (returning to Testing Item Selection List
Screen) is illustrated below by specific patterns.
(1) Visual Check, Semiautomatic Check (except
SWITCH Test) and Measurement Check
Exit is made using a key displayed on the LCD bottom
line.
Pressing the [CANCEL] key before completing a test
forces it to terminate, but NG will be displayed on the
right side of the corresponding testing item. (This
indicates that the test is not completed yet.) If the
[ENTER] key is pressed in the middle of the test, it will
be invalidated.
(2) SWITCH Test
∗∗
Diag Mode Ver. 1.00
∗∗
Total Result [ ]
14. LCD
15. PANEL LED-2
11. MY-SLOT
12. WORD CLOCK
13. GPI
Fig. 6. Testing Item Selection List Screen (2)
∗∗∗
23.
∗∗∗
NG: [CANCEL]
OK: [ENTER] ,
PANEL LED-2
Fig. 7. Visual Check, Semiautomatic Check (except
SWITCH Test) and Measurement Check Screen
∗∗∗
18.
∗∗∗
NG: [HOME]
H i t t h e K e y
[ SCENE
]
S w i t c h
Fig. 8. SWITCH Test Screen
∗∗∗
09.
∗∗∗
EXIT: [ENTER]
NG: DATA ERROR!
[ SCENE
]
M I D I
Fig. 9. Automatic Check Test Screen (1)
∗∗∗
13.
∗∗∗
WCLK:
WORD CLOCK
44.1K 88.2K
48K 96K
EXIT: [CANCEL]
Exec: [ENTER] ,
SEL WCLK: [UP/DOWN]
Fig. 10. Automatic Check Test Screen (2)
∗∗∗
13.
∗∗∗
INT.
WCLK OK !
WORD CLOCK
EXIT: [ENTER]
Fig. 11. Automatic Check Test Screen (3)
Summary of Contents for DME24N
Page 48: ...DME24N DME64N 48 DM Circuit Board B B to DSP CN100 to DSP CN101 2NAP WC06240 02 1 ...
Page 49: ...49 DME24N DME64N B B Pattern side パターン側 2NAP WC06240 02 1 ...
Page 50: ...DME24N DME64N 50 DSP Circuit Board C C to DM CN251 to DC CN105 to DM CN250 2NAP WC0670 01 1 ...
Page 51: ...51 DME24N DME64N C C Component side 部品側 2NAP WC0670 01 1 ...
Page 52: ...DME24N DME64N 52 DSP Circuit Board DSP Circuit Board D D ...
Page 53: ...53 DME24N DME64N Component side 部品側 2 layer 2層 D D ...
Page 54: ...DME24N DME64N 54 DSP Circuit Board E E ...
Page 55: ...55 DME24N DME64N Component side 部品側 3 layer 3層 E E ...
Page 56: ...DME24N DME64N 56 DSP Circuit Board F F 2NAP WC0670 02 1 ...
Page 57: ...57 DME24N DME64N Pattern side パターン側 F F 2NAP WC0670 02 1 ...
Page 59: ...59 DME24N DME64N Pattern side パターン側 2NA WC31440 02 1 AD Circuit Board DME24N ...
Page 62: ...DME24N DME64N 62 H H DA Circuit Board DME24N 2NA WC06570 02 1 ...
Page 66: ...DME24N DME64N 66 CA Circuit Board DME64N J J 2NAP WC06410 02 ...
Page 67: ...67 DME24N DME64N Pattern side パターン側 J J 2NAP WC06410 02 ...
Page 75: ...75 DME24N DME64N Pattern side パターン側 JK Circuit Board DME24N 2NA WC31440 02 1 ...
Page 79: ...79 DME24N DME64N Pattern side パターン側 2NAP WC06430 02 1 P P P P MY Circuit Board DME64N ...