Chapter 3
Main Panel Window
DME Designer Owner’s Manual
56
■
Security Level
User security levels are set with the [Operation Security] item at the right of the “Security” dialog
box.
You can allow or disallow editing and the ability to open windows or set controls.
Ten levels, 1 through 10, are set for scene storage/recall and user controls. Level 1 is the highest
level and 10 is the lowest. By default, level 1 is set for the [Administrator] user. Level 1 can be set
for the [Administrator] only. Users created by the [Administrator] directly below itself can be set at
levels 2 through 10. New users created subordinate to users at level 2 can be set at levels 3
through 10. New users can be created no higher than one level below the user that created them.
Scene sets the level for storing and recalling scenes. The logged on user can store or recall scenes
at levels equal to or lower than his or her own level. For example, a user at level 3 can recall scenes
set for scene recall at levels 3 through 10.
Levels are also set for user control. The logged on user can display or edit user controls at levels
equal to or lower than his or her own level.
The log-on user can use zones that are checked in the [View Zone] field.
Level 1 User
Level 2 User
Level 3 User
Level 4 User
Security Level Settings
User Level
High
Low