Setting the SCSI ID of the Internal MO Drive
193
D24—Owner’s Manual
Appendix
Setting the SCSI ID of the Internal MO Drive
Setting the SCSI ID of the internal MO disk drive involves removing the D24’s top cover
and setting the DIP switch located on the MO drive’s circuit board.
This procedure should be carried out by a qualified engineer. If in doubt, contact your
Yamaha dealer.
1
Remove the top-cover fixing
screws (11), as shown here.
2
Remove the top cover.
3
Using a small flat-bladed screw-
driver, or something similar, set
DIP switches 1 through 3, as
listed below, to achieve the
required SCSI ID.
SCSI IDs 6 and 7 are not listed, since they are reserved for other purposes.
SCSI ID
DIP switch number
1
2
3
5
ON
OFF
ON
4
ON
OFF
OFF
3
OFF
ON
ON
2 (default)
OFF
ON
OFF
1
OFF
OFF
ON
0
OFF
OFF
OFF
12
34
56
78
O
FF