Global functions
60
Output metering
[Function]
Display the output levels of MIX channels 1–48, MATRIX channels 1–24, STEREO A/B channels, MONITOR
OUT jacks A/B, and CUE OUT jacks. The location at which the output levels are measured can also be
selected.
■
Console
In the
LCD FUNCTION ACCESS
block, press the
[METER]
switch
(press repeatedly until the screen
shown at the right appears)
■
Display
MENU
button
→
METER
button
→
tab for the desired channel
[Screen functions]
1
Meters
These are peak level meters that show the output lev-
els from the various channels and output jacks.
The current master level is shown in the number box
located below.
The
∑
and CLIP meter will light if clipping occurs at
a metering point, PRE EQ, POST EQ, POST COMP,
or INSERT IN point in the currently selected chan-
nel.
However, the MONITOR A/B CUE meter does not
have a
∑
or CLIP indicator.
2
Pairing icon
This shows the channel number and the pairing status.
By clicking this area, you can set/defeat pairing.
3
METERING POINT
You can pre-specify metering points for PRE and
POST, and then use the PRE button and POST but-
ton to switch between the two selected metering
points.
The following metering points can be selected for
each.
PRE button
•
PRE EQ
.............. Immediately before the EQ
•
PRE FADER
....... Immediately before the fader
POST button
•
POST FADER
.... Immediately after the fader
•
POST ON
........... After the [ON] switch
1
2
4
3
Summary of Contents for CS1D
Page 14: ...Owner s Manual ...
Page 18: ...Operating Manual ...
Page 19: ...Operating Manual Start up ...
Page 68: ...Operating Manual Basic Operation ...
Page 227: ...Reference Manual ...
Page 228: ...Reference Manual Hardware ...
Page 345: ...Reference Manual Software ...
Page 543: ...Reference Manual Appendices ...