CP1 Data List
13
Bank Select
Bulk Dump Block
MIDI Data Table
Available Bank Select/Program Change
Parameter Base Address
“Top Address” indicates the top address of each block designated by bulk dump operation.
“Byte Count” indicates the data size contained in each block designated by bulk dump
operation.
The Block from the Bulk Header to the Bulk Footer of the Performance can be received
regardless their order. They can be received even if all of them are not transmitted. They
cannot be received if the irrelevant Block is included.
To execute 1 Performance bulk dump request, designate its corresponding Bulk Header
address.
When the Multiple Bulk Control Footer is received, Performances will be saved to the Flash
ROM.
For the information about “mm” and “nn” shown in the following list, refer to MIDI
PARAMETER CHANGE TABLE (BULK CONTROL) below.
MSB (HEX)
LSB
(HEX)
Program
No.
Type
Memory
Description
63
3F
61
3D
0 – 15
Performance
PRE A
When Keyboard Mode
(KbdMode) is set to
“layer” or “split”, this MIDI
data is received via the
Basic Receive Channel
(RecvCh). When
Keyboard Mode
(KbdMode) is set to
“zone”, this MIDI data is
received via Channel 1 or
2.
62
3E
0 – 15
PRE B
63
3F
0 – 15
PRE C
64
40
0 – 15
USR A
65
41
0 – 15
USR B
66
42
0 – 15
USR C
68
44
0 – 15
EXT A
69
45
0 – 15
EXT B
70
46
0 – 15
EXT C
Parameter Block
Description
Top Address
H
M
L
SYSTEM
00
00
00
System
00
20
00
Master EQ
BULK CONTROL
0E
00
00
Header
0F
00
00
Footer
MULTIPLE BULK CONTROL
10
00
00
Header
11
00
00
Footer
PERFORMANCE COMMON
30
00
00
Performance Common
PERFORMANCE PART
31
00
00
Part 1
31
01
00
Part 2
31
10
00
Pre-Amp Part 1
31
11
00
Pre-Amp Part 2
31
20
00
Modulation Part 1
31
21
00
Modulation Part 2
31
30
00
Power-Amp Part 1
31
31
00
Power-Amp Part 2
PERFORMANCE ZONE
32
00
00
Zone 1
:
32
03
00
Zone 4
Parameter Block
Description
Byte Count
Top Address
Dec
Hex
H
M
L
SYSTEM
System
60
3C
00
00
00
Master EQ (for Voice Mode)
22
16
00
20
00
PERFORMANCE
Bulk Header
0
00
0E
mm
nn
COMMON
Common
68
44
30
00
00
Reverb
38
26
30
01
00
Controller (PB, FC1, FC2, FS)
30
1E
30
05
00
Assignable Knob
30
1E
30
06
00
PART
Part 1
48
30
31
00
00
Part 2
48
30
31
01
00
Pre-Amp Part 1
38
26
31
10
00
Pre-Amp Part 2
38
26
31
11
00
Modulation Part 1
38
26
31
20
00
Modulation Part 2
38
26
31
21
00
Power-Amp Part 1
38
26
31
30
00
Power-Amp Part 2
38
26
31
31
00
MASTER KEYBOARD
ZONE
Zone 1
16
10
32
00
00
:
4 Blocks
Zone 4
16
10
32
03
00
Bulk Footer
0
00
0F
mm