7-5
Chapter
7
RS-232C INTERF
ACE
3.2
Transmission mode and communication parameters
Transmission mode
Full duplex
Synchronous system
Start-stop synchronization
Baud rate [bps]
4800, [9600], 19200, 38400, 57600
Character length [bit]
[8], 7
Stop bit [bit]
[1], 2
Parity
[Odd], even, none
Termination code
[CRLF], CR
Flow control
[XON/XOFF], RTS/CTS, none
Receive buffer
1024 bytes
Transmit buffer
1024 bytes
Numbers or items in brackets [ ] indicate settings after initialization.
n
NOTE
1) Termination code
• Robot transmit
When CRLF (carriage line feed) is selected:
Transmits data with a CR code (0DH) and LF code (0AH) added at the
end of a line.
When CR (carriage return) is selected:
Transmits data with a CR code (0DH) added at the end of a line.
• Robot receive
Receives data by treating entries made up to the CR code as 1 line and
ignoring the LF code, regardless of which termination code is selected.
2) If the "Display language" parameter is set to "JAPANESE" in "SYSTEM" mode,
then set the character length to 8 bits.
Katakana letters (Japanese phonetic) cannot be output from the
communication port if set to 7 bits.
3. Communication specifications
Summary of Contents for CEmarking RCX221
Page 2: ......
Page 6: ...4 MEMO...
Page 16: ......
Page 30: ......
Page 38: ......
Page 62: ...3 24 MEMO...
Page 68: ......
Page 342: ......
Page 366: ...5 24 MEMO...
Page 368: ......
Page 384: ......
Page 396: ......
Page 404: ...8 8 MEMO...
Page 406: ......
Page 467: ...MEMO...